Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 513 |
|
Vulkan F60/200 oxygen cylinder pressure reducer DIN 477-1, 0 - 60 bar according to ISO 2503, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to DIN EN ISO 5171, without shut-off valve, with metal diaphragm for pure gases up to 5.0, max. inlet pressure: 200 bar, outlet pressure: adjustable 0 - 60 bar, max. output: 140 Nm³/h air at 60 bar back pressure, inlet: G3/4 RH U-nut according to DIN 477-1 No. 9, outlet (optional special outlet): G1/4 RHk according to EN 560, inlet gauge: 0 - 315/200 bar, outlet gauge: 0 - 100/60 bar, width x height x depth: 210 x 190 x 75 mm. This cylinder pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - External thread G1/4" RHk according to EN560 Options: Item number Gas purity Outlet connection 218375-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 218375-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 218375-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/2" RHk according to EN 560 218375-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 218375-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 218375-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 218375-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm |
|
|
|
|
|
| 1154 |
|
<p>Vulkan F10/200 Effect compressed air cylinder pressure reducer DIN 477-1, 0-10 bar according to ISO 2503 with pre-pressure compensation for constant back pressure under all operating conditions, single-stage design, with shut-off valve, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 0-10 bar adjustable, maximum output: 48 Nm³/h compressed air at 10 bar back pressure. Inlet: G 5/8 RHaf connection screw according to DIN 477-1 No. 13, Outlet (optional special outlet): G 1/4 RHk x 6 mm nozzle according to EN 560, input pressure gauge: 0-315/200 bar, output pressure gauge: 0-16/10 bar, width x height x depth: 210 x 190 x 75 mm. This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard:- for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge):- for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard:- G1/4 RHk x 6 mm nozzle according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 207005 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 207005-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 207005-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 207005-870 for technical gases up to 4.5, with Standard membrane external thread G3/8" RHk according to EN 560 207005-838 for technical gases up to 4.5, with standard membrane external thread G1/2" RHk according to EN 560 207005-6M for technical gases up to 4.5, with standard membrane compression fitting VA 6mm 207005-8M for technical gases up to 4.5, with standard membrane compression fitting VA 8mm 207005-10M for technical gases up to 4.5, with standard membrane compression fitting VA 10mm 207005-12M for technical gases up to 4.5, with standard membrane compression fitting VA 12mm 207005-2 for technical gases up to 4.5, with standard membrane compression fitting VA 1/8" 207005-4 for technical gases up to 4.5, with standard diaphragm compression fitting VA 1/4" 207005-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G1/4" RHk x 6mm 207005-MM-812 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" RHk x 9mm 207005-MM-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/4" RHk according to EN560 207005-MM-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" RHk according to EN 560 207005-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 207005-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 207005-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207005-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207005-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207005-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 207005-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
|
| 3071 |
|
<p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p> |
|
|
|
|
|
| 3315 |
|
Vulkan F10/2 NP test gas cylinder pressure reducer DIN 477-1, 200 bar, 0 - 250 mbar<br />Standards & Design:<br /><br />two-stage design, consisting of F10/200 with straight outlet and LP216, , 420904 fully assembled with safety gauges according to ISO 5171<br />according to DIN 477-1<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 200 bar<br />• Output pressure: 0 - 250 mbar adjustable<br />• Inlet: M19x1<br />• Outlet: G 3/8 LHk x 9mm hose nozzle according to DIN EN 560<br /><br />Dimensions:<br /><br />Width x Height x Depth: 380 x 250 x 110 mm |
|
|
|
|
|
| 3318 |
|
Vulkan F10/200 nitrogen cylinder pressure reducer DIN 477-1, 0-10 bar<br />Standards & Design:<br /><br />according to ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve<br />according to DIN 477-1 No<br />according to EN 560<br /><br />Functional elements:<br /><br />• shut-off valve<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 200 bar<br />• outlet pressure<br />• Output pressure: 0-10 bar<br />• Inlet: W 24<br />• Outlet: G 1/4 RHk x 6 mm hose nozzle according to EN 560<br />• Inlet pressure gauge: 0-315/200 bar<br />• Outlet pressure gauge: 0-16/10 bar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 230 x 75 mm |
|
|
|
|
|
| 3319 |
|
<p>Vulkan F15/2 100 nitrous oxide N2O cylinder pressure reducer DIN 477-1, 0 - 1.5 bar<br>Standards & Design:<br><br>according to DIN EN ISO 2503, Class 0, two-stage design, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve<br>according to DIN 477-1 No<br>according to EN 560<br><br>Functional elements:<br><br>• shut-off valve<br><br>Technical data:<br><br>• Maximum inlet pressure: 100 bar<br>• outlet pressure<br>• Output pressure: 0 - 1<br>• Inlet: G3/8RH U-nut according to DIN 477-1 No<br>• Outlet: G 1/4 RHk x 6mm nozzle according to EN 560<br>• Inlet pressure gauge: 0 - 160/100 bar<br>• Outlet pressure gauge: 0 - 2<br><br>Dimensions:<br><br>Width x Height x Depth: 240 x 190 x 75 mm</p> |
|
|
|
|
|
| 3505 |
|
<p>Vulkan F60/200 Effect compressed air cylinder pressure reducer DIN 477-1, 0 - 60 bar according to ISO 2503, with pre-pressure compensation for constant back pressure under all working conditions, single-stage design, without shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 0 - 60 bar adjustable, maximum output: 140 Nm³/h compressed air at 60 bar back pressure, inlet: G5/8RHaf A-screw according to DIN 477-1 No. 13, outlet (optional special outlet): G1/4RHk according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 210 x 210 x 75 mm. This cylinder pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- External thread G1/4" RHk according to EN560 Options: Article numberGas purityOutlet connection 207375-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207375-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207375-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/2" RHk according to EN 560 207375-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207375-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207375-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207375-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm</p> |
|
|
|
|
|
| 3687 |
|
Vulkan F15/200 2F Argon cylinder pressure reducer with 2 flow meters, 0.5-5 Nl/min, 4.5 bar according to ISO 2503, Class 20. Single-stage design with two flow meters for monitoring the exact flow rate in Nl/min. With pre-pressure compensation for constant outlet pressure when the pre-pressure drops, with safety pressure gauge according to ISO 5171, and with shut-off valve. Maximum inlet pressure: 200 bar. Outlet pressure: 2 x 4.5 bar, fixed output. Output: 2 x 0.5 - 5.0 Nl/min. Ar/CO2 adjustable. Inlet: W 21.8 x 1/14 RH U-nut according to DIN 477-1, No. 6. Outlet: 2x G 1/4 RHk x 6mm nozzle according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 250 x 230 x 75 mm. Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
|
| 4691 |
|
<p>Vulkan F20/200 Effect Oxygen cylinder pressure reducer DIN 477-1, 0-20 bar according to ISO 2503, Class 5, single-stage design, burnout tested according to ISO 2503, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0-20 bar adjustable. Maximum output: 75 Nm³/h at 20 bar outlet pressure. Inlet: G3/4RH U-nut according to DIN 477-1 No. 9. Outlet (optional special outlet): G1/4RHk x 6 mm nozzle according to EN 560. Inlet gauge: 0-315/200 bar. Outlet gauge: 0-40/20 bar. Width x Height x Depth: 210 x 210 x 75 mm. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/4 RHk x 6 mm nozzle according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208300 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 208300-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 208300-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208300-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 208300-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 208300-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 208300-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 208300-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 208300-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 208300-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 208300-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 208300-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 208300-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 208300-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208300-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208300-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 208300-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208300-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208300-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208300-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208300-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 208300-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
|
| 5076 |
|
Vulkan F15/200 2F Effect 2 cylinder pressure reducer with flowmeter H2 3-32 Nl/min. 4.5 bar according to ISO 2503, Class 20. Single-stage design with two flowmeters for monitoring the exact flow rate in Nl/min. With pre-pressure compensation for constant back pressure when the pre-pressure drops. With safety pressure gauge according to ISO 5171 and shut-off valve. Maximum inlet pressure: 200 bar. Outlet pressure: 2 x 4.5 bar, fixed output. Output: 2 x 3.0 - 32.0 Nl/min. Hydrogen adjustable. Inlet: W21.8x1/14LH U-nut according to DIN 477-1, No. 1. Outlet: 2x G 3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 210 x 230 x 75 mm. Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
|
| 6840 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|
|
| 6843 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|
|