Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 6961 |
|
<p>free of oil- and grease, for hydrogen an forming gas,consisting of: 2 HP shut-off valve, 2 pressure regulator H40 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p>
<p>inlet pressure max: 300 bar<br><br>outlet pressure: 25 bar fixed<br><br>flow max: 125 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1.095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "H", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>With note labeld: "not for oxygen use"</p> |
|
|
|
|
|
| 6962 |
|
<p>free of oil- and grease, for hydrogen and forming gas, consisting of: 2 HP shut-off valve, 2 pressure regulator H20 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), electric cable blue, length 2.000mm</p>
<p>2 solenoid valves 230VAC, <br><br>1 double non return valve and <br><br>2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate<br><br>inlet pressure max: 300 bar<br><br>outlet pressure: 15 bar fixed<br><br>flow max: 75 Nm³/h air at 15 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 300 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "H", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>with warning note:"not to use with oxygen"</p> |
|
|
|
|
|
| 6963 |
|
<p>free of oil- and grease, for nitrogen and compressed air,consisting of: 2 HP shut-off valve, 2 pressure regulator H40 acc. to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 40 bar fixed<br><br>flow max: 125 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1.095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>With sticker "Not for oxygen use"</p> |
|
|
|
|
|
| 6964 |
|
<p>free of oil- and grease, for nitrogen, compressed air and helium use, consisting of: 2 HP shut-off valve, 2 pressure regulator HR40 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p>
<p>inlet pressure max: 300 bar<br><br>outlet pressure: 40 bar fixed<br><br>flow max: 250 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1095 x 320 x 160 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>labeld with sticker "not for oxygen use"</p> |
|
|
|
|
|
| 6965 |
|
<p>free of oil- and grease, for oxygen,consisting of: 2 HP shut-off valve, 2 pressure regulator H40 acc to ISO 7291, single stage, adiabatic compression tested, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p>
<p>inlet pressure max: 300 bar<br><br>outlet pressure: 25 bar fixed<br><br>flow max: 125 Nm³/h air at 25 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1.095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 6966 |
|
<p>Automatic manifold Vulkan 300 bar Linde free of oil- and grease, for oxygen,consisting of: 2 HP shut-off valve, 2 pressure regulator H20 acc to ISO 7291, single stage, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p>
<p>inlet pressure max: 300 bar<br><br>outlet pressure: 15 bar fixed<br><br>flow max: 75 Nm³/h air at 15 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 300 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The product fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 6967 |
|
<p>free of oil- and grease, for MISON,consisting of: 2 HP shut-off valve, 2 pressure regulator HR20 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 20 bar fixed<br><br>flow max: 160 Nm³/h air at 20 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 475 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>with warning note:"not to use with oxygen"</p> |
|
|
|
|
|
| 6968 |
|
<p>free of oil- and grease, for oxygen use, consisting of: 2 HP shut-off valve, 2 pressure regulator HR40 acc. to ISO 7291, adiabatic compression tested acc. to ISO 7291 single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 25 bar fixed<br><br>flow max: 250 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|