SELECT 
  cscart_ult_product_descriptions.product_id, 
  cscart_ult_product_descriptions.short_description, 
  IF(
    cscart_ult_product_descriptions.short_description = "", 
    cscart_ult_product_descriptions.full_description, 
    ""
  ) AS full_description, 
  cscart_ult_product_descriptions.meta_keywords, 
  cscart_ult_product_descriptions.meta_description, 
  cscart_ult_product_descriptions.search_words, 
  cscart_ult_product_descriptions.promo_text 
FROM 
  cscart_ult_product_descriptions 
WHERE 
  cscart_ult_product_descriptions.product_id IN (
    1154, 3315, 3318, 3687, 5076, 4691, 3071, 
    513, 3505, 3319, 3306, 3296, 1172, 1173, 
    4917, 4918, 3430, 3429, 3437, 3436, 
    3438, 3500, 3501, 3431, 6948, 3499, 
    3455, 3466, 3454, 3456, 3449, 3461, 
    3441, 3444, 3471, 3442, 3480, 3448, 
    3440, 3467, 3468, 3435, 3476, 3447, 
    3439, 3465, 3446, 3460
  ) 
  AND cscart_ult_product_descriptions.company_id = 1 
  AND cscart_ult_product_descriptions.lang_code = 'en'

Query time 0.00100

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "37.86"
    },
    "table": {
      "table_name": "cscart_ult_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id",
        "company_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code",
        "company_id"
      ],
      "key_length": "13",
      "rows_examined_per_scan": 48,
      "rows_produced_per_join": 48,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_ult_product_descriptions`.`company_id` = 1) and (`gaseus`.`cscart_ult_product_descriptions`.`product_id` in (1154,3315,3318,3687,5076,4691,3071,513,3505,3319,3306,3296,1172,1173,4917,4918,3430,3429,3437,3436,3438,3500,3501,3431,6948,3499,3455,3466,3454,3456,3449,3461,3441,3444,3471,3442,3480,3448,3440,3467,3468,3435,3476,3447,3439,3465,3446,3460)) and (`gaseus`.`cscart_ult_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "33.06",
        "eval_cost": "4.80",
        "prefix_cost": "37.86",
        "data_read_per_join": "183K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "company_id",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text
513 Vulkan F60/200 oxygen cylinder pressure reducer DIN 477-1, 0 - 60 bar according to ISO 2503, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to DIN EN ISO 5171, without shut-off valve, with metal diaphragm for pure gases up to 5.0, max. inlet pressure: 200 bar, outlet pressure: adjustable 0 - 60 bar, max. output: 140 Nm³/h air at 60 bar back pressure, inlet: G3/4 RH U-nut according to DIN 477-1 No. 9, outlet (optional special outlet): G1/4 RHk according to EN 560, inlet gauge: 0 - 315/200 bar, outlet gauge: 0 - 100/60 bar, width x height x depth: 210 x 190 x 75 mm. This cylinder pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - External thread G1/4" RHk according to EN560 Options: Item number Gas purity Outlet connection 218375-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 218375-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 218375-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/2" RHk according to EN 560 218375-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 218375-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 218375-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 218375-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm
1172 Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4"
1173 Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4"
3071 <p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p>
3315 Vulkan F10/2 NP test gas cylinder pressure reducer DIN 477-1, 200 bar, 0 - 250 mbar<br />Standards & Design:<br /><br />two-stage design, consisting of F10/200 with straight outlet and LP216, , 420904 fully assembled with safety gauges according to ISO 5171<br />according to DIN 477-1<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 200 bar<br />• Output pressure: 0 - 250 mbar adjustable<br />• Inlet: M19x1<br />• Outlet: G 3/8 LHk x 9mm hose nozzle according to DIN EN 560<br /><br />Dimensions:<br /><br />Width x Height x Depth: 380 x 250 x 110 mm
3318 Vulkan F10/200 nitrogen cylinder pressure reducer DIN 477-1, 0-10 bar<br />Standards & Design:<br /><br />according to ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve<br />according to DIN 477-1 No<br />according to EN 560<br /><br />Functional elements:<br /><br />• shut-off valve<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 200 bar<br />• outlet pressure<br />• Output pressure: 0-10 bar<br />• Inlet: W 24<br />• Outlet: G 1/4 RHk x 6 mm hose nozzle according to EN 560<br />• Inlet pressure gauge: 0-315/200 bar<br />• Outlet pressure gauge: 0-16/10 bar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 230 x 75 mm
3429 single stage, with safety gauges acc. to ISO 5171inlet pressure max: 60 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 90 Nm³/h compressed air at 20 bar outlet pressure<br />in- and outlet: G3/8 RH female<br />inlet gauge: 0- 100/60 bar<br />outlet gauge: 0 – 40/20 bar <br />width x height x depth: 220 x 200 x 75 mm <br />with label on regulator
3430 einstufige Bauart, mit Sicherheitsmanometern nach ISO 5171, Eingangsdruck max: 40 bar<br />Ausgangsdruck: 0 – 20 bar regelbar<br />Leistung max: 90 Nm³/h Druckluft bei 20 bar Hinterdruck <br />Ein- und Ausgang: Klemmring Ms 12 mm<br />ohne Eingangsmanometer<br />Ausgangsmanometer: 0 – 40/20 bar senkrecht<br />Breite x Höhe x Tiefe: 220 x 200 x 75 mm <br />mit Typenschild auf Druckminderer, mit Werkszeugnis 2.2 Bedienungsanleitung, Etikett mit Lindenummer/öl- und fettfrei auf Folie und Karton
3431 <p>acc. ISO 7291, single stage, with safety pressure gauges acc. ISO 5171</p><p>inlet pressure max: 25 bar<br><br>outlet pressure: 0 – 1,5 bar regelbar<br><br>Flow max: 18 Nm³/h at 1,5 bar outlet pressure <br><br>inlet connection: M24x1,5RHak male<br><br>outlet connection: M24x1,5RHak male<br><br>inlet pressure gauge: 0 – 40/ 25 bar<br><br>outlet pressure gauge: 0 – 2,5/ 1,5 bar<br><br>Width x heighth x depth: 232 x 185 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape and certificate 2.2</p>
3435 single stage with safety gauge acc. to ISO 5171, inlet pressure max: 20 bar<br />outlet pressure: 0 – 4 bar adjustable<br />flow max: 10 kg/h at 4 bar working pressure<br />inlet: W 21,8x1/14 LH nut acc. to DIN 477<br />outlet: G 3/8 LHk x 9 mm tail-piece EN 560<br />outlet gauge: 0 – 6/4 bar<br />width x height x depth: 198 x 134 x 75 mm<br />with Linde-Logo on body, with Linde-tape and Linde operating manual<br />
3436 In-line regulator for non aggressive gasesnot to use for: He/H2/C2H2/C3H8/CH4/C2H2<br />inlet pressure: max. 40 bar<br />working pressure : 0 - 20 bar adjustable<br />membrane : PTFE coatet<br />inlet gauge: without <br />working gauge : acc. to ISO 5171, 0- 40/20 bar<br />inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br />flow : max. 90 m3/h<br />free of oil- and grease<br />width x height x depth: 220 x 200 x 75 mm <br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2
3437 <p>single stage, inlet pressure: max. 40 bar</p><p>working pressure : 0 - 20 bar adjustable<br><br>diaphragm: PTFE coatet<br><br>inlet gauge: without <br><br>working gauge : acc. to ISO 5171, 0- 40/20 bar<br><br>inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br><br>flow : max. 90 m3/h compresse air at 20 bar working pressure<br><br>free of oil- and grease<br><br>width x height x depth: 220 x 200 x 75 mm <br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
3438 In-line regulator, single stage,inlet pressure: max. 40 bar<br />working pressure : 0 - 20 bar adjustable<br />membrane : PTFE coatet<br />inlet gauge: without <br />working gauge : acc. to ISO 5171, 0- 40/20 bar<br />inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br />flow : max. 90 m3/h<br />free of oil- and grease<br />width x height x depth: 220 x 200 x 75 mm <br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2
3439 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,<br />with shut off valve<br />inlet pressure max:200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max:48 Nm³/h air at 10 bar outlet pressure <br />inlet connection: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RH x 6mm tail-piece acc. EN560<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3440 <p>acc to DIN EN ISO 2503, class 3, double stage, with safety gauges acc. to DIN ISO 5171, with shut off valve</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3441 according to DIN EN ISO 2503, with inlet pressure compensation for constant downstream pressure when the inlet pressure falls, with safety pressure gauges in accordance with ISO 5171, with shut-off valveInput pressure max: 200 bar<br />Output pressure: 0 – 30.0 bar<br />Performance: 40 Nm³/h compressed air at 30 bar back pressure<br />Input: W 24.32x1/14 RH Ü-nut according to DIN 477-1, No. 10<br />Output: G 3/8 RHk x 9 mm hose nozzle according to EN 560<br />Input pressure gauge: 0 – 315/200 bar<br />Output pressure gauge: 0 - 60/40 bar<br />Width x Height x Depth: 210 x 230 x 75 mm<br />with Linde logo on the housing, with Linde operating instructions and Linde adhesive tape
3442 <p>acc to DIN EN ISO 2503 class 0, double stage, with safety gauges acc. to DIN ISO 5171, including shut off valve</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 1,5 bar adjustable<br><br>flow max: 5 Nm³/h air at 1,5 bar outlet pressure <br><br>inlet: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk male with 6 mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 2,5/1,5 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3444 acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: W24,32x1/14RHf nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3447 acc. to ISO 2503, class 3, single stage, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max.: 48 Nm³/h air at 10 bar working pressure<br />Inlet connection: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br />outlet connection:G 3/8 RHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3448 <p>acc to DIN EN ISO 2503, class 3, double stage, with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br><br>outlet: G 3/8 LHk male with 9mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm</p>
3449 acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3454 acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: W 21,8x1/14 RH Ü-Mutter nach DIN 477-1, No. 6<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box
3455 acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: W 24,32x1/14 RH Ü-Mutter nach DIN 477-1, No. 10<br />Ausgang:G 1/4 RHk x 6 mm Tülle nach EN 560<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge:0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box
3456 <p>acc to DIN EN ISO 2503, class 5, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 20 bar adjustable<br><br>flow max: 75 Nm³/h at 20 bar working pressure<br><br>inlet connection: W21,8x1/14RHf nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RH x 6mm tail-piece<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 40/ 20 bar<br><br>width x height x depth: 210 x 210 x 75 mm</p>
3460 compressed air, acc. to ISO 2503, class 3, single stage, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max.: 48 Nm³/h air at 10 bar working pressure<br />Inlet connection: G 5/8 RH screw acc. to DIN 477-1, no. 13<br />outlet connection:G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3461 acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: G5/8RH screw acc. to DIN 477-1, no. 13<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3465 acc to DIN EN ISO 2503, class 3, single stage, adiabatic compression tested acc. to DIN EN ISO 2503,with safety gauges acc. to DIN ISO 5171<br />inlet pressure max:200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max:48 Nm³/h air at 10 bar outlet pressure <br />inlet connection: G ¾ RH nut acc. to DIN 477<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 16/ 10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3466 acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: G3/4 RH Ü-Mutter nach DIN 477-1, No. 9<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box
3467 <p>acc to DIN EN ISO 2503,class 3, double stage, adiabatic compression tested acc. to DIN EN ISO 2503,with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: G3/4RH nut acc. to DIN 477-1, no. 9<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3468 <p>nach ISO 2503, Klasse 5, zweistufige Bauart, mit Vordruckausgleich für konstanten Hinterdruck bei fallendem Vordruck, mit Sicherheitsmanometern nach ISO 5171, mit AbsperrventilEingangsdruck max: 200 bar</p><p>Ausgangsdruck: 0 – 20 bar regelbar<br><br>Leistung max: 60 Nm³/h Druckluft bei 20 bar Hinterdruck <br><br>Eingang: G 3/4 RH Ü-Mutter nach DIN 477-1<br><br>Ausgang:G 3/8 RHk x 9 mm Tülle nach EN 560<br><br>Eingangsmanometer:0 – 315/200 bar<br><br>Ausgangsmanometer: 0 – 40/20 bar<br><br>Breite x Höhe x Tiefe: 240 x 210 x 75 mm<br><br>mit Linde-Logo auf Gehäuse, mit Linde-Bedienungsanleitung und Linde-Klebeband</p>
3471 acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure, with metal diaphragm, with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: G3/4RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3476 <p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 48 Nm³/h at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RH x 6mm tail-piece<br><br>inlet gauge: 0 – 315/200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3480 <p>acc to DIN EN ISO 2503,class 3, double stage, with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W21,8x1/14RH nut acc. to DIN 477-1, no. 6<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm</p>
3499 According to DIN EN ISO 7291, single-stage design, with safety pressure gaugesDIN ISO 5171, chrome-plated lifter, hard PVC locking cone, with metal membrane,<br />Inlet pressure max: 300 bar<br />Output pressure: 0 – 10 bar adjustable<br />Output max: 90 Nm³/h compressed air at 10 bar back pressure<br />Input (rear): M 24x1.5 RHk - S16 Ü-nut<br />Output: G3/4RH x 18mm solder socket<br />Input pressure gauge: 0 – 400/300 bar<br />Output pressure gauge: 0 – 16/10 bar<br />Blow-off valve with mounted Cu pipe bend (270°, 10x1 mm)<br />Width x Height x Depth: 160 x 326 x 108 mm<br />With manufacturer's declaration, operating instructions, shrink-wrapped in food-safe foil with sticker with Linde number/oil and fat-free on cardboard, individually packed in foamed cardboard, with Linde adhesive tape, "glass fork symbol" (according to Regulation (EC) 1935/2004, Annex II) on foil and cardboard, code letter "N".<br />The pressure reducer meets the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and the LFGB and is suitable for contact with food gases.<br />Factory certificate 2.2 and test report<br />With sticker, nameplate and warning “not for oxygen”
3500 <p>free of oil- and grease, for oxygen, acc. to ISO 7291 with metal diaphragm, single stage, adiabatic compression tested acc. to ISO 7291, with safety gauges acc. to ISO 5171inlet pressure max: 300 bar</p><p>outlet pressure: 0 – 40 bar adjustable<br><br>flow max: 125 Nm³/h compr. air at 40 bar outlet pressure <br><br>inlet (on the back): M 24x1,5 RHk - S16 nut<br><br>outlet: G3/4RH x 18mm brazing connection<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 60/40 bar<br><br>width x height x depth: 170 x 200 x 106 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
3501 free of oil- and grease, for oxygen, acc. to ISO 7291 with metal diaphragm, single stage, adiabatic compression tested acc. to ISO7291, with safety gauges acc. to ISO 5171inlet pressure max: 300 bar<br />outlet pressure: 15 – 40 bar adjustable<br />flow max: 250 Nm³/h compr. air at 40 bar outlet pressure <br />inlet (on the back): M 24x1,5 RHk - S16 nut<br />outlet: G3/4RH x 18mm brazing connection<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 200 x 330 x 110 mm<br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2
3505 <p>Vulkan F60/200 Effect compressed air cylinder pressure reducer DIN 477-1, 0 - 60 bar according to ISO 2503, with pre-pressure compensation for constant back pressure under all working conditions, single-stage design, without shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 0 - 60 bar adjustable, maximum output: 140 Nm³/h compressed air at 60 bar back pressure, inlet: G5/8RHaf A-screw according to DIN 477-1 No. 13, outlet (optional special outlet): G1/4RHk according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 210 x 210 x 75 mm. This cylinder pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- External thread G1/4" RHk according to EN560 Options: Article numberGas purityOutlet connection 207375-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207375-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207375-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/2" RHk according to EN 560 207375-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207375-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207375-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207375-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm</p>
3687 Vulkan F15/200 2F Argon cylinder pressure reducer with 2 flow meters, 0.5-5 Nl/min, 4.5 bar according to ISO 2503, Class 20. Single-stage design with two flow meters for monitoring the exact flow rate in Nl/min. With pre-pressure compensation for constant outlet pressure when the pre-pressure drops, with safety pressure gauge according to ISO 5171, and with shut-off valve. Maximum inlet pressure: 200 bar. Outlet pressure: 2 x 4.5 bar, fixed output. Output: 2 x 0.5 - 5.0 Nl/min. Ar/CO2 adjustable. Inlet: W 21.8 x 1/14 RH U-nut according to DIN 477-1, No. 6. Outlet: 2x G 1/4 RHk x 6mm nozzle according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 250 x 230 x 75 mm. Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel membrane SS321 (1.4541).
4917 Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4"
4918 Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4"
5076 Vulkan F15/200 2F Effect 2 cylinder pressure reducer with flowmeter H2 3-32 Nl/min. 4.5 bar according to ISO 2503, Class 20. Single-stage design with two flowmeters for monitoring the exact flow rate in Nl/min. With pre-pressure compensation for constant back pressure when the pre-pressure drops. With safety pressure gauge according to ISO 5171 and shut-off valve. Maximum inlet pressure: 200 bar. Outlet pressure: 2 x 4.5 bar, fixed output. Output: 2 x 3.0 - 32.0 Nl/min. Hydrogen adjustable. Inlet: W21.8x1/14LH U-nut according to DIN 477-1, No. 1. Outlet: 2x G 3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 210 x 230 x 75 mm. Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel membrane SS321 (1.4541).
6948 free of oil- and grease, acc. to ISO 7291, with metal diaphragm, single stage, with safety gauges acc. to ISO 5171inlet pressure max: 100 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 75 Nm³/h compr. air at 20 bar outlet pressure <br />inlet: (rear): M 24x1,5 RHk - S16 nut<br />outlet: G3/4RH x 18mm brazing piece<br />relief valve with mounted copper pipe bend (270 °, 10x1 mm)<br />inlet gauge: 0 – 160/100 bar<br />working gauge: 0 – 40/20 bar<br />width x height x depth: 170 x 200 x 106 mm<br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2<br />with sticker "not for oxygen use"<br /><br />Due to the cooling energy evolving from the decompression, the output of the regulator is strongly limited and does not comply with the above mentioned value indicated for the use of compressed air.<br />For continously high flow the additional use of a gas pre heater may be necessary.