Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 1572 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 1599 |
|
Main and line pressure reducer for oxygen 10-100 bar Vulkan LHR200/100 DIN according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 10 - 100 bar, output: 380 Nm?/h (compressed air) at 50 bar outlet pressure and 100 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477 Part 1, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 160/100 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 208765 G1/2RHak according to EN 560 208765-800 External thread G1/4" RHk according to EN560 208765-870 External thread G3/8" RHk according to EN 560 208765-6M Compression fitting VA 6mm 208765-8M Compression fitting VA 8mm 208765-10M Compression fitting VA 10mm 208765-12M Compression fitting VA 12mm 208765-15M Compression fitting VA 15mm 208765-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1653 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2224 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
|
| 2509 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2603 |
|
Vulkan LHR 300/100 BSP nitrogen cylinder pressure reducer DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet: W30x2RH U-nut according to DIN 477-5. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 303760 G1/2RHak according to EN 560 303760-800 External thread G1/4" RHk according to EN560 303760-870 External thread G3/8" RHk according to EN 560 303760-6M Compression fitting VA 6mm 303760-8M Compression fitting VA 8mm 303760-10M Compression fitting VA 10mm 303760-12M Compression fitting VA 12mm 303760-15M Compression fitting VA 15mm 303760-18M compression fitting VA 18mm |
|
|
|
|
|
| 6002 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 6105 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 6106 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 6107 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 6108 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 6191 |
|
Vulkan LHR 300/200 nitrogen cylinder pressure reducer DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 200 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W30x2RH U-nut according to DIN 477-5. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 303770 G1/2RHak according to EN 560 303770-800 External thread G1/4" RHk according to EN560 303770-870 External thread G3/8" RHk according to EN 560 303770-6M Compression fitting VA 6mm 303770-8M Compression fitting VA 8mm 303770-10M Compression fitting VA 10mm 303770-12M Compression fitting VA 12mm 303770-15M Compression fitting VA 15mm 303770-18M compression fitting VA 18mm |
|
|
|
|
|