Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
| 1172 |
|
Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4" |
|
|
|
|
| 1173 |
|
Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4" |
|
|
|
|
| 3431 |
|
<p>acc. ISO 7291, single stage, with safety pressure gauges acc. ISO 5171</p><p>inlet pressure max: 25 bar<br><br>outlet pressure: 0 – 1,5 bar regelbar<br><br>Flow max: 18 Nm³/h at 1,5 bar outlet pressure <br><br>inlet connection: M24x1,5RHak male<br><br>outlet connection: M24x1,5RHak male<br><br>inlet pressure gauge: 0 – 40/ 25 bar<br><br>outlet pressure gauge: 0 – 2,5/ 1,5 bar<br><br>Width x heighth x depth: 232 x 185 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape and certificate 2.2</p> |
|
|
|
|
| 3454 |
|
acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: W 21,8x1/14 RH Ü-Mutter nach DIN 477-1, No. 6<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box |
|
|
|
|
| 3455 |
|
acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: W 24,32x1/14 RH Ü-Mutter nach DIN 477-1, No. 10<br />Ausgang:G 1/4 RHk x 6 mm Tülle nach EN 560<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge:0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box |
|
|
|
|
| 3466 |
|
acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: G3/4 RH Ü-Mutter nach DIN 477-1, No. 9<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box |
|
|
|
|
| 3499 |
|
According to DIN EN ISO 7291, single-stage design, with safety pressure gaugesDIN ISO 5171, chrome-plated lifter, hard PVC locking cone, with metal membrane,<br />Inlet pressure max: 300 bar<br />Output pressure: 0 – 10 bar adjustable<br />Output max: 90 Nm³/h compressed air at 10 bar back pressure<br />Input (rear): M 24x1.5 RHk - S16 Ü-nut<br />Output: G3/4RH x 18mm solder socket<br />Input pressure gauge: 0 – 400/300 bar<br />Output pressure gauge: 0 – 16/10 bar<br />Blow-off valve with mounted Cu pipe bend (270°, 10x1 mm)<br />Width x Height x Depth: 160 x 326 x 108 mm<br />With manufacturer's declaration, operating instructions, shrink-wrapped in food-safe foil with sticker with Linde number/oil and fat-free on cardboard, individually packed in foamed cardboard, with Linde adhesive tape, "glass fork symbol" (according to Regulation (EC) 1935/2004, Annex II) on foil and cardboard, code letter "N".<br />The pressure reducer meets the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and the LFGB and is suitable for contact with food gases.<br />Factory certificate 2.2 and test report<br />With sticker, nameplate and warning “not for oxygen” |
|
|
|
|
| 3500 |
|
<p>free of oil- and grease, for oxygen, acc. to ISO 7291 with metal diaphragm, single stage, adiabatic compression tested acc. to ISO 7291, with safety gauges acc. to ISO 5171inlet pressure max: 300 bar</p><p>outlet pressure: 0 – 40 bar adjustable<br><br>flow max: 125 Nm³/h compr. air at 40 bar outlet pressure <br><br>inlet (on the back): M 24x1,5 RHk - S16 nut<br><br>outlet: G3/4RH x 18mm brazing connection<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 60/40 bar<br><br>width x height x depth: 170 x 200 x 106 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 3501 |
|
free of oil- and grease, for oxygen, acc. to ISO 7291 with metal diaphragm, single stage, adiabatic compression tested acc. to ISO7291, with safety gauges acc. to ISO 5171inlet pressure max: 300 bar<br />outlet pressure: 15 – 40 bar adjustable<br />flow max: 250 Nm³/h compr. air at 40 bar outlet pressure <br />inlet (on the back): M 24x1,5 RHk - S16 nut<br />outlet: G3/4RH x 18mm brazing connection<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 200 x 330 x 110 mm<br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2 |
|
|
|
|
| 4917 |
|
Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4" |
|
|
|
|
| 4918 |
|
Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4" |
|
|
|
|
| 6948 |
|
free of oil- and grease, acc. to ISO 7291, with metal diaphragm, single stage, with safety gauges acc. to ISO 5171inlet pressure max: 100 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 75 Nm³/h compr. air at 20 bar outlet pressure <br />inlet: (rear): M 24x1,5 RHk - S16 nut<br />outlet: G3/4RH x 18mm brazing piece<br />relief valve with mounted copper pipe bend (270 °, 10x1 mm)<br />inlet gauge: 0 – 160/100 bar<br />working gauge: 0 – 40/20 bar<br />width x height x depth: 170 x 200 x 106 mm<br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2<br />with sticker "not for oxygen use"<br /><br />Due to the cooling energy evolving from the decompression, the output of the regulator is strongly limited and does not comply with the above mentioned value indicated for the use of compressed air.<br />For continously high flow the additional use of a gas pre heater may be necessary. |
|
|
|
|