SELECT 
  cscart_seo_names.object_id AS product_id, 
  cscart_seo_names.name AS seo_name, 
  cscart_seo_names.path AS seo_path 
FROM 
  cscart_seo_names 
WHERE 
  cscart_seo_names.object_id IN (
    2280, 2327, 2328, 2329, 2330, 2394, 2395, 
    2396, 2397, 2398, 2399, 2400
  ) 
  AND cscart_seo_names.type = "p" 
  AND cscart_seo_names.dispatch = "" 
  AND cscart_seo_names.lang_code = 'en' 
  AND (
    cscart_seo_names.company_id = 1 
    OR cscart_seo_names.company_id = 0
  )

Query time 0.00048

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "16.81"
    },
    "table": {
      "table_name": "cscart_seo_names",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "dispatch"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "object_id",
        "type",
        "dispatch",
        "lang_code",
        "company_id"
      ],
      "key_length": "210",
      "rows_examined_per_scan": 24,
      "rows_produced_per_join": 24,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_seo_names`.`object_id` in (2280,2327,2328,2329,2330,2394,2395,2396,2397,2398,2399,2400)) and (`gaseus`.`cscart_seo_names`.`type` = 'p') and (`gaseus`.`cscart_seo_names`.`dispatch` = '') and (`gaseus`.`cscart_seo_names`.`lang_code` = 'en') and ((`gaseus`.`cscart_seo_names`.`company_id` = 1) or (`gaseus`.`cscart_seo_names`.`company_id` = 0)))",
      "cost_info": {
        "read_cost": "14.41",
        "eval_cost": "2.40",
        "prefix_cost": "16.81",
        "data_read_per_join": "40K"
      },
      "used_columns": [
        "name",
        "object_id",
        "company_id",
        "type",
        "dispatch",
        "path",
        "lang_code"
      ]
    }
  }
}

Result

product_id seo_name seo_path
2280 main-and-line-pressure-regulator-hydrogen-0-200-bar-vulkan-lhr300-200-bsp-en-6-en 265/266/271/308
2327 main-and-line-pressure-regulator-oxygen-0-200-bar-vulkan-lhr300-200-bsp-en-7-en 265/266/271/308
2328 main-and-line-pressure-regulator-oxygen-0-200-bar-vulkan-lhr300-200-bsp-en-5-en 265/266/271/308
2329 main-and-line-pressure-regulator-oxygen-0-200-bar-vulkan-lhr300-200-bsp-en-3-en 265/266/271/308
2330 main-and-line-pressure-regulator-oxygen-0-200-bar-vulkan-lhr300-200-bsp-en-en 265/266/271/308
2394 main-and-line-pressure-regulator-compressed-air-0-200-bar-vulkan-lhr300-200-bsp-en-8-en 265/266/271/308
2395 main-and-line-pressure-regulator-compressed-air-0-200-bar-vulkan-lhr300-200-bsp-en-6-en 265/266/271/308
2396 main-and-line-pressure-regulator-compressed-air-0-200-bar-vulkan-lhr300-200-bsp-en-4-en 265/266/271/308
2397 main-and-line-pressure-regulator-compressed-air-0-200-bar-vulkan-lhr300-200-bsp-en-2-en 265/266/271/308
2398 main-and-line-pressure-regulator-compressed-air-0-200-bar-vulkan-lhr300-200-bsp-en-9 265/266/271/308
2399 main-and-line-pressure-regulator-helium-0-200-bar-vulkan-lhr300-200-bsp-en-7-en 265/266/271/308
2400 main-and-line-pressure-regulator-helium-0-200-bar-vulkan-lhr300-200-bsp-en-5-en 265/266/271/308