SELECT 
  cscart_product_descriptions.product_id, 
  cscart_product_descriptions.short_description, 
  IF(
    cscart_product_descriptions.short_description = '' 
    OR cscart_product_descriptions.short_description IS NULL, 
    cscart_product_descriptions.full_description, 
    ''
  ) AS full_description, 
  cscart_product_descriptions.meta_keywords, 
  cscart_product_descriptions.meta_description, 
  cscart_product_descriptions.search_words, 
  cscart_product_descriptions.promo_text, 
  cscart_product_descriptions.unit_name 
FROM 
  cscart_product_descriptions 
WHERE 
  cscart_product_descriptions.product_id IN (
    3443, 3469, 3464, 3459, 6950, 3470, 3457, 
    3462, 3450, 3458, 3463, 3451, 3445, 
    3472, 3481, 3482, 3475, 3483, 3474, 
    3473, 3426, 6949, 3427, 3477
  ) 
  AND cscart_product_descriptions.lang_code = 'en'

Query time 0.00048

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "28.91"
    },
    "table": {
      "table_name": "cscart_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code"
      ],
      "key_length": "9",
      "rows_examined_per_scan": 24,
      "rows_produced_per_join": 24,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_product_descriptions`.`product_id` in (3443,3469,3464,3459,6950,3470,3457,3462,3450,3458,3463,3451,3445,3472,3481,3482,3475,3483,3474,3473,3426,6949,3427,3477)) and (`gaseus`.`cscart_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "26.51",
        "eval_cost": "2.40",
        "prefix_cost": "28.91",
        "data_read_per_join": "109K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text",
        "unit_name"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text unit_name
3426 <p>acc. to DIN EN ISO 2503, class 20, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valvesinlet pressure max: 200 bar</p><p>outlet pressure: 2x 2,5 bar pre adjusted<br><br>flow: 2 x 3,0 - 30,0 Nl/min. adjustable<br><br>inlet: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape<br><br><br><br>Replaces article 2264551189</p>
3427 <p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 4 – 42 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3443 acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3445 acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max: 140 Nm³/h at 60 bar working pressure<br />inlet connection: W24,32x1/14 RHf nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RHak acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3450 acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: W21,8x1/14LHf nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8LH x 9mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3451 acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max: 140 Nm³/h at 60 bar working pressure<br />inlet connection: W21,8x1/14LHf nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8LHak acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3457 <p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 40 bar adjustable<br><br>flow max: 120 Nm³/h at 40 bar working pressure<br><br>inlet connection: W21,8x1/14RHf nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RH x 6mm tail-piece<br><br>inlet gauge: 0 – 315/200 bar<br><br>working gauge: 0 – 60/40 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3458 <p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 60 bar adjustable<br><br>flow max: 140 Nm³/h at 60 bar working pressure<br><br>inlet connection: W21,8x1/14 RHf nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RHak acc. to EN560<br><br>inlet gauge: 0 – 315/200 bar<br><br>working gauge: 0 – 100/60 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3459 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3462 acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: G5/8RH screw acc. to DIN 477-1, no. 13<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3463 acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max: 140 Nm³/h at 60 bar working pressure<br />inlet connection: G5/8RH screw acc. to DIN 477-1, no. 13<br />outlet connection: G 1/4RH acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3464 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />Inlet connection: G 5/8 RHaf screw acc. to DIN 477-1, no. 13<br />Outlet connection: G 5/8 RHif acc. to DIN 477-1, no. 13<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3469 acc to DIN EN ISO 2503, class 5, single stage, adiabatic compression tested acc. to DIN EN ISO 2503, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 75 Nm³/h at 20 bar working pressure<br />inlet connection: G3/4 RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 40/ 20 bar<br />width x height x depth: 210 x 210 x 75 mm
3470 acc. to ISO 2503, single stage with safety gauges acc. to ISO 5171inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: G3/4 RH nut acc. to DIN 477-1, no. 9<br />outlet connection: G 3/4 RH male acc. to DIN 477-1, no. 9<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 150 x 210 x 120 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3472 acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure, with metal diaphragm, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max:140 Nm³/h at 60 bar working pressure<br />inlet connection: G3/4 RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RHak acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3473 <p>acc to DIN EN ISO 2503, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 4 bar pre adjusted<br><br>flow: 8,5 - 85 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3474 <p>acc to ISO 2503, class 20, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 4,5 bar pre adjusted<br><br>flow: 5,0 – 50,0 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br><br><br>replaces item 223615</p>
3475 acc to DIN EN ISO 2503, class 10, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 1,5 bar fixed<br />flow: 2,0 - 23,0 Nl/min. forming gas adjustable<br />Inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8 LHk x 9mm tailpiece EN 560<br />inlet gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 230 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3477 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 20 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3481 <p>acc to DIN EN ISO 2503, class 10, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar fixed<br><br>flow: 1,0 – 14,0 Nl/min. argon adjustable<br><br>Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4 RHk x 6mm tailpiece EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 210 x 230 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3482 <p>acc to ISO 2503, class 20, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 2,5 bar pre adjusted<br><br>flow: 1,0 – 30 Nl/min. adjustable<br><br>inlet: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6,<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br>With Linde-Logo stamped on body, with Linde operating manual and Linde tape<br><br><br><br>replaces article 22645589!</p>
3483 acc to DIN EN ISO 2503, class 20, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauge acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 2,5 bar fixed<br />flow: 3-30 Nl/min. Mison adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6mm tailpiece EN 560<br />inlet gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 230 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
6949 <p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 2-23 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 1<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
6950 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br />outlet connection: W24,32x1/14RH male acc. to DIN 477-1, no. 10<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape