Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 3426 |
|
<p>acc. to DIN EN ISO 2503, class 20, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valvesinlet pressure max: 200 bar</p><p>outlet pressure: 2x 2,5 bar pre adjusted<br><br>flow: 2 x 3,0 - 30,0 Nl/min. adjustable<br><br>inlet: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape<br><br><br><br>Replaces article 2264551189</p> |
|
|
|
|
|
| 3427 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 4 – 42 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3445 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max: 140 Nm³/h at 60 bar working pressure<br />inlet connection: W24,32x1/14 RHf nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RHak acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3472 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure, with metal diaphragm, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max:140 Nm³/h at 60 bar working pressure<br />inlet connection: G3/4 RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RHak acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3473 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 4 bar pre adjusted<br><br>flow: 8,5 - 85 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3474 |
|
<p>acc to ISO 2503, class 20, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 4,5 bar pre adjusted<br><br>flow: 5,0 – 50,0 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br><br><br>replaces item 223615</p> |
|
|
|
|
|
| 3475 |
|
acc to DIN EN ISO 2503, class 10, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 1,5 bar fixed<br />flow: 2,0 - 23,0 Nl/min. forming gas adjustable<br />Inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8 LHk x 9mm tailpiece EN 560<br />inlet gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 230 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3477 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 20 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3481 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar fixed<br><br>flow: 1,0 – 14,0 Nl/min. argon adjustable<br><br>Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4 RHk x 6mm tailpiece EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 210 x 230 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3482 |
|
<p>acc to ISO 2503, class 20, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 2,5 bar pre adjusted<br><br>flow: 1,0 – 30 Nl/min. adjustable<br><br>inlet: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6,<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br>With Linde-Logo stamped on body, with Linde operating manual and Linde tape<br><br><br><br>replaces article 22645589!</p> |
|
|
|
|
|
| 3483 |
|
acc to DIN EN ISO 2503, class 20, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauge acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 2,5 bar fixed<br />flow: 3-30 Nl/min. Mison adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6mm tailpiece EN 560<br />inlet gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 230 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 6949 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 2-23 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 1<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|