Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 2277 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2278 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2279 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2280 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2327 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2328 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2329 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2330 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2394 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2395 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2396 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2397 |
|
Vulkan LHR 300/200 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 200 bar, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 200 bar, adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304770 G1/2RHak according to EN 560 304770-800 External thread G1/4" RHk according to EN560 304770-870 External thread G3/8" RHk according to EN 560 304770-6M Compression fitting VA 6mm 304770-8M Compression fitting VA 8mm 304770-10M Compression fitting VA 10mm 304770-12M Compression fitting VA 12mm 304770-15M Compression fitting VA 15mm 304770-18M compression fitting VA 18mm |
|
|
|
|
|
| 2510 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 2511 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 2512 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 2513 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 2756 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2757 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2758 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2759 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2760 |
|
Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2761 |
|
<p>Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm</p> |
|
|
|
|
|
| 2762 |
|
Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2763 |
|
Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2764 |
|
Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2818 |
|
Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm |
|
|
|
|
|
| 2819 |
|
Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm |
|
|
|
|
|
| 2820 |
|
Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm |
|
|
|
|
|
| 2821 |
|
<p>Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm</p> |
|
|
|
|
|
| 2822 |
|
Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm |
|
|
|
|
|
| 2933 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2934 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2935 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 2936 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 3612 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 3613 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 3614 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 3615 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 3837 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 3838 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 3839 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 4224 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 4225 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 4226 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 4227 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 4228 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 4229 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 4230 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5079 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5080 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5081 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5082 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5083 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5084 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5085 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5086 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5087 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5088 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5089 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5090 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5091 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5092 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5093 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5094 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5095 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5096 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5097 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5098 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5099 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5100 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5101 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5102 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5103 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5104 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5105 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 5106 |
|
<p>Vulkan LR40 Effect Helium in-line ribbed pressure reducer, 15-40 bar based on ISO 7291, single-stage design, with pre-pressure compensation for constant downstream pressure with falling upstream pressure, with safety gauges according to ISO 5171, with metal diaphragm, maximum inlet pressure: 100 bar, outlet pressure: 15-40 bar, adjustable, maximum output: 280 Nm³/h compressed air at 40 bar downstream pressure. Inlet: external thread G3/4RHak - EN 560, Outlet: external thread G3/4RHak - EN 560, input pressure gauge: 0-160/100 bar, output pressure gauge: 0-60/40 bar, width x height x depth: 220 x 280 x 85 mm. This in-line ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G3/4" RHak on both sides according to EN 560 Options (surcharge): Order number Gas purity/membrane Inlet/outlet screw connection 10664626 for technical gases up to 4.5, with standard membrane on both sides. external thread G3/4" RHak according to EN 560 10664626-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 10664626-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 10664626-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 10664626-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 10664626-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 10664626-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 10664626-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G3/4" RHak according to EN 560 10664626-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 6mm stainless steel compression fitting. 10664626-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting. 10664626-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting. 10664626-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting. 10664626-MM-15M-15M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 15mm stainless steel compression fitting. 10664626-MM-18M-18M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) on both sides. 18mm stainless steel compression fitting.</p> |
|
|
|
|
|
| 6109 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 6110 |
|
Vulkan LHR 300/100 BSP cylinder pressure reducer for fuel gases DIN 477-5, 10 - 100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W30x2LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 100 / 160 bar. Width x Height x Depth: 150 x 210 x 120 mm. Weight: approx. 1.2 kg. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 304760 G1/2RHak according to EN 560 304760-800 External thread G1/4" RHk according to EN560 304760-870 External thread G3/8" RHk according to EN 560 304760-6M Compression fitting VA 6mm 304760-8M Compression fitting VA 8mm 304760-10M Compression fitting VA 10mm 304760-12M Compression fitting VA 12mm 304760-15M Compression fitting VA 15mm 304760-18M compression fitting VA 18mm |
|
|
|
|
|
| 6343 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6344 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6345 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6346 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6347 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for compressed air, DIN 477-1, 10-200 bar according to ISO 2503, single-stage design, with safety gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10-200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: G5/8RHaf A-screw according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 207770 G1/2RHak according to EN 560 207770-800 External thread G1/4" RHk according to EN560 207770-870 External thread G3/8" RHk according to EN 560 207770-6M Compression fitting VA 6mm 207770-8M Compression fitting VA 8mm 207770-10M Compression fitting VA 10mm 207770-12M Compression fitting VA 12mm 207770-15M Compression fitting VA 15mm 207770-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6348 |
|
Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6349 |
|
Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6350 |
|
Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6351 |
|
Vulkan LHR 200/100 BSP compressed air cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure, input: G5/8RHaf A-screw according to DIN 477-1, output: G1/2RHak according to EN560, input pressure gauge: 0 - 315/200 bar, output pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 207760 G1/2RHak according to EN 560 207760-800 External thread G1/4" RHk according to EN560 207760-870 External thread G3/8" RHk according to EN 560 207760-6M Compression fitting VA 6mm 207760-8M Compression fitting VA 8mm 207760-10M Compression fitting VA 10mm 207760-12M Compression fitting VA 12mm 207760-15M Compression fitting VA 15mm 207760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6404 |
|
Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm |
|
|
|
|
|
| 6405 |
|
<p>Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm</p> |
|
|
|
|
|
| 6406 |
|
Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm |
|
|
|
|
|
| 6407 |
|
<p>Cylinder pressure reducer Vulkan LHR 200/200 BSP Helium DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 200 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 315/200 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20677026 G1/2RHak according to EN 560 20677026-800 External thread G1/4" RHk according to EN560 20677026-870 External thread G3/8" RHk according to EN 560 20677026-6M Compression fitting VA 6mm 20677026-8M Compression fitting VA 8mm 20677026-10M Compression fitting VA 10mm 20677026-12M Compression fitting VA 12mm 20677026-15M Compression fitting VA 15mm 20677026-18M compression fitting VA 18mm</p> |
|
|
|
|
|
| 6517 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6518 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6519 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6520 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|
| 6521 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10-100 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 10-100 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/160 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 204760 G1/2RHak according to EN 560 204760-800 External thread G1/4" RHk according to EN560 204760-870 External thread G3/8" RHk according to EN 560 204760-6M Compression fitting VA 6mm 204760-8M Compression fitting VA 8mm 204760-10M Compression fitting VA 10mm 204760-12M Compression fitting VA 12mm 204760-15M Compression fitting VA 15mm 204760-18M Compression fitting VA 18mm |
|
|
|
|
|