Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
| 3452 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 30 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 30 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 30 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
| 3453 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
| 3477 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 20 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3478 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape |
|
|
|
|
| 3479 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 30 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3488 |
|
according to ISO 2503, class 3,single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3491 |
|
acc. to ISO 2503, class3, with high pressure compensation, single stage with safety gauges acc. to DIN ISO 5171inlet pressure max:300 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max: 48 Nm³/h at 10 bar outlet pressure<br />inlet connection: W 30x2LHk nut acc. to DIN 477-5, Nr. 57<br />outlet connection: G 3/8 LHk x 9mm tail-piece acc. to DIN EN 560<br />inlet gauge: 0 – 400 / 300 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3497 |
|
according to ISO 2503, class 3, adiabatic compression tested, single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 59<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 6840 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|
| 6843 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|