Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 1566 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 1567 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 1568 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 1569 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 1570 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 1571 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 1600 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1601 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1602 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1603 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1604 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1605 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1606 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1607 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1608 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1609 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1610 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1611 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1612 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1613 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1614 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1615 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1616 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1617 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1618 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1619 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1620 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1621 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1622 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1623 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1624 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1625 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 1627 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1628 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1629 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1630 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1631 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1632 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1633 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1634 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1635 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 1636 |
|
Main and line pressure reducer Vulkan LHR 200/200 DIN oxygen DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, max. inlet pressure: 200 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar pre-pressure, inlet: G 3/4 RHf U-nut according to DIN 477-1, outlet: G 3/4 RHaf according to DIN 477-1, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 208775 G1/2RHak according to EN 560 208775-800 External thread G1/4" RHk according to EN560 208775-870 External thread G3/8" RHk according to EN 560 208775-6M Compression fitting VA 6mm 208775-8M Compression fitting VA 8mm 208775-10M Compression fitting VA 10mm 208775-12M Compression fitting VA 12mm 208775-15M Compression fitting VA 15mm 208775-18M Compression fitting VA 18mm |
|
|
|
|
|
| 5245 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5246 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5247 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5248 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5249 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5250 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5251 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5252 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5253 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5254 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5255 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5256 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5257 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5258 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5259 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5260 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5261 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5262 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5263 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5264 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5265 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5266 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5267 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5268 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5269 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5270 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5271 |
|
Vulkan LHR 300/100 DIN oxygen cylinder pressure regulator DIN 477-5, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar inlet pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5. Outlet: G 3/4 RHaf according to DIN 477 Part 1. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. Important note for 300 bar pressure regulators - please check. Your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308765 G1/2RHak according to EN 560 308765-800 External thread G1/4" RHk according to EN560 308765-870 External thread G3/8" RHk according to EN 560 308765-6M Compression fitting VA 6mm 308765-8M Compression fitting VA 8mm 308765-10M Compression fitting VA 10mm 308765-12M Compression fitting VA 12mm 308765-15M Compression fitting VA 15mm 308765-18M compression fitting VA 18mm |
|
|
|
|
|
| 5299 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5300 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5301 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5302 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5303 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5304 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5305 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5306 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5307 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5308 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5309 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5310 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5311 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5312 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5313 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5314 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5315 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5316 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5317 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5318 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5319 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5320 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5321 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5322 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5323 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5324 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|
| 5325 |
|
Vulkan LHR 300/200 DIN oxygen cylinder pressure reducer according to DIN 477-5, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 300 bar, adjustable outlet pressure: 10 - 200 bar, output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 300 bar pre-pressure, inlet: W 30 x 2 RH U-nut according to DIN 477 Part 5, outlet: G 3/4 RHaf according to DIN 477 Part 1, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 308775 G1/2RHak according to EN 560 308775-800 External thread G1/4" RHk according to EN560 308775-870 External thread G3/8" RHk according to EN 560 308775-6M Compression fitting VA 6mm 308775-8M Compression fitting VA 8mm 308775-10M Compression fitting VA 10mm 308775-12M Compression fitting VA 12mm 308775-15M Compression fitting VA 15mm 308775-18M compression fitting VA 18mm |
|
|
|
|
|