Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
| 3435 |
|
single stage with safety gauge acc. to ISO 5171, inlet pressure max: 20 bar<br />outlet pressure: 0 – 4 bar adjustable<br />flow max: 10 kg/h at 4 bar working pressure<br />inlet: W 21,8x1/14 LH nut acc. to DIN 477<br />outlet: G 3/8 LHk x 9 mm tail-piece EN 560<br />outlet gauge: 0 – 6/4 bar<br />width x height x depth: 198 x 134 x 75 mm<br />with Linde-Logo on body, with Linde-tape and Linde operating manual<br /> |
|
|
|
|
| 3439 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,<br />with shut off valve<br />inlet pressure max:200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max:48 Nm³/h air at 10 bar outlet pressure <br />inlet connection: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RH x 6mm tail-piece acc. EN560<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3440 |
|
<p>acc to DIN EN ISO 2503, class 3, double stage, with safety gauges acc. to DIN ISO 5171, with shut off valve</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
| 3441 |
|
according to DIN EN ISO 2503, with inlet pressure compensation for constant downstream pressure when the inlet pressure falls, with safety pressure gauges in accordance with ISO 5171, with shut-off valveInput pressure max: 200 bar<br />Output pressure: 0 – 30.0 bar<br />Performance: 40 Nm³/h compressed air at 30 bar back pressure<br />Input: W 24.32x1/14 RH Ü-nut according to DIN 477-1, No. 10<br />Output: G 3/8 RHk x 9 mm hose nozzle according to EN 560<br />Input pressure gauge: 0 – 315/200 bar<br />Output pressure gauge: 0 - 60/40 bar<br />Width x Height x Depth: 210 x 230 x 75 mm<br />with Linde logo on the housing, with Linde operating instructions and Linde adhesive tape |
|
|
|
|
| 3442 |
|
<p>acc to DIN EN ISO 2503 class 0, double stage, with safety gauges acc. to DIN ISO 5171, including shut off valve</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 1,5 bar adjustable<br><br>flow max: 5 Nm³/h air at 1,5 bar outlet pressure <br><br>inlet: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk male with 6 mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 2,5/1,5 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
| 3443 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3444 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: W24,32x1/14RHf nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3447 |
|
acc. to ISO 2503, class 3, single stage, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max.: 48 Nm³/h air at 10 bar working pressure<br />Inlet connection: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br />outlet connection:G 3/8 RHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3448 |
|
<p>acc to DIN EN ISO 2503, class 3, double stage, with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br><br>outlet: G 3/8 LHk male with 9mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm</p> |
|
|
|
|
| 3449 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3456 |
|
<p>acc to DIN EN ISO 2503, class 5, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 20 bar adjustable<br><br>flow max: 75 Nm³/h at 20 bar working pressure<br><br>inlet connection: W21,8x1/14RHf nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RH x 6mm tail-piece<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 40/ 20 bar<br><br>width x height x depth: 210 x 210 x 75 mm</p> |
|
|
|
|
| 3459 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3460 |
|
compressed air, acc. to ISO 2503, class 3, single stage, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max.: 48 Nm³/h air at 10 bar working pressure<br />Inlet connection: G 5/8 RH screw acc. to DIN 477-1, no. 13<br />outlet connection:G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3461 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: G5/8RH screw acc. to DIN 477-1, no. 13<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3464 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />Inlet connection: G 5/8 RHaf screw acc. to DIN 477-1, no. 13<br />Outlet connection: G 5/8 RHif acc. to DIN 477-1, no. 13<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3465 |
|
acc to DIN EN ISO 2503, class 3, single stage, adiabatic compression tested acc. to DIN EN ISO 2503,with safety gauges acc. to DIN ISO 5171<br />inlet pressure max:200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max:48 Nm³/h air at 10 bar outlet pressure <br />inlet connection: G ¾ RH nut acc. to DIN 477<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 16/ 10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3467 |
|
<p>acc to DIN EN ISO 2503,class 3, double stage, adiabatic compression tested acc. to DIN EN ISO 2503,with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: G3/4RH nut acc. to DIN 477-1, no. 9<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
| 3468 |
|
<p>nach ISO 2503, Klasse 5, zweistufige Bauart, mit Vordruckausgleich für konstanten Hinterdruck bei fallendem Vordruck, mit Sicherheitsmanometern nach ISO 5171, mit AbsperrventilEingangsdruck max: 200 bar</p><p>Ausgangsdruck: 0 – 20 bar regelbar<br><br>Leistung max: 60 Nm³/h Druckluft bei 20 bar Hinterdruck <br><br>Eingang: G 3/4 RH Ü-Mutter nach DIN 477-1<br><br>Ausgang:G 3/8 RHk x 9 mm Tülle nach EN 560<br><br>Eingangsmanometer:0 – 315/200 bar<br><br>Ausgangsmanometer: 0 – 40/20 bar<br><br>Breite x Höhe x Tiefe: 240 x 210 x 75 mm<br><br>mit Linde-Logo auf Gehäuse, mit Linde-Bedienungsanleitung und Linde-Klebeband</p> |
|
|
|
|
| 3469 |
|
acc to DIN EN ISO 2503, class 5, single stage, adiabatic compression tested acc. to DIN EN ISO 2503, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 75 Nm³/h at 20 bar working pressure<br />inlet connection: G3/4 RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 40/ 20 bar<br />width x height x depth: 210 x 210 x 75 mm |
|
|
|
|
| 3471 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure, with metal diaphragm, with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: G3/4RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 3476 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 48 Nm³/h at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RH x 6mm tail-piece<br><br>inlet gauge: 0 – 315/200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
| 3480 |
|
<p>acc to DIN EN ISO 2503,class 3, double stage, with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W21,8x1/14RH nut acc. to DIN 477-1, no. 6<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm</p> |
|
|
|
|
| 6950 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br />outlet connection: W24,32x1/14RH male acc. to DIN 477-1, no. 10<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|