SELECT 
  cscart_ult_product_descriptions.product_id, 
  cscart_ult_product_descriptions.short_description, 
  IF(
    cscart_ult_product_descriptions.short_description = "", 
    cscart_ult_product_descriptions.full_description, 
    ""
  ) AS full_description, 
  cscart_ult_product_descriptions.meta_keywords, 
  cscart_ult_product_descriptions.meta_description, 
  cscart_ult_product_descriptions.search_words, 
  cscart_ult_product_descriptions.promo_text 
FROM 
  cscart_ult_product_descriptions 
WHERE 
  cscart_ult_product_descriptions.product_id IN (
    3452, 3478, 3479, 3453, 3491, 3488, 3497, 
    3495, 3489, 3492, 3496, 3490
  ) 
  AND cscart_ult_product_descriptions.company_id = 1 
  AND cscart_ult_product_descriptions.lang_code = 'en'

Query time 0.00044

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "9.47"
    },
    "table": {
      "table_name": "cscart_ult_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id",
        "company_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code",
        "company_id"
      ],
      "key_length": "13",
      "rows_examined_per_scan": 12,
      "rows_produced_per_join": 12,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_ult_product_descriptions`.`company_id` = 1) and (`gaseus`.`cscart_ult_product_descriptions`.`product_id` in (3452,3478,3479,3453,3491,3488,3497,3495,3489,3492,3496,3490)) and (`gaseus`.`cscart_ult_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "8.27",
        "eval_cost": "1.20",
        "prefix_cost": "9.47",
        "data_read_per_join": "45K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "company_id",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text
3452 <p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 30 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 30 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 30 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3453 <p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3478 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape
3479 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 30 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3488 according to ISO 2503, class 3,single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3489 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3490 acc. to ISO 2503, single stage with safety gauges acc. to ISO5171inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3491 acc. to ISO 2503, class3, with high pressure compensation, single stage with safety gauges acc. to DIN ISO 5171inlet pressure max:300 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max: 48 Nm³/h at 10 bar outlet pressure<br />inlet connection: W 30x2LHk nut acc. to DIN 477-5, Nr. 57<br />outlet connection: G 3/8 LHk x 9mm tail-piece acc. to DIN EN 560<br />inlet gauge: 0 – 400 / 300 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3492 acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 300 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W30x2LH nut acc. to DIN 477-5 no. 57<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 400/300 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3495 acc. to ISO 2503, single stage with safety gauges acc. to ISO 5171inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3496 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3497 according to ISO 2503, class 3, adiabatic compression tested, single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 59<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape