| 1433 |
|
Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541). |
|
|
|
|
| 1489 |
|
Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 right according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
| 1494 |
|
Main pressure reducer Vulkan H40/200 Effect Inert Gas right for AM 40-25 bar according to ISO 7291, single-stage design, burnout tested according to ISO 7291, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 25 bar fixed. Maximum output: 120 Nm³/h at 40 bar back pressure. Inlet: External thread M24x1.5RHak-16S. Outlet: Union nut G1/2RHk according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 210 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar fixed) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 1499 |
|
Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
| 1504 |
|
Main pressure reducer Vulkan H40/200 Effect fuel gas DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 204540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 204540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 204540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 204540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 204540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 204540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 204540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 204540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 204540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 204540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 204540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 204540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 204540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 204540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 204540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 204540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 204540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 204540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 1516 |
|
Main pressure reducer Vulkan H20/200 Effect Oxygen right for AM35/AM35H according to DIN EN ISO 7291, single-stage design, burnout tested according to ISO 7291, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 20 bar fixed. Maximum output: 75 Nm³/h at 20 bar back pressure. Inlet: external thread M24x1.5RHak-16S, Outlet: union nut G1/2RHk according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 40 / 20 bar. Width x Height x Depth: 210 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for automatic changeover group AM35/AM35H (20 bar fixed) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm SS321 (1.4541). |
|
|
|
|
| 2185 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2186 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2187 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2188 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2268 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
| 2269 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
| 2270 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
| 2765 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2766 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2767 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2768 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2823 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 2824 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 2825 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 2826 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 2827 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 2828 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 2829 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 2830 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 2831 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 2841 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2842 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2843 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2844 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 2928 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 2929 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 2930 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 2931 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 2932 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 3024 |
|
Vulkan LHR 200/200 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 200 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RH, threaded connection according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203770 G1/2RHak according to EN 560 203770-800 External thread G1/4" RHk according to EN560 203770-870 External thread G3/8" RHk according to EN 560 203770-6M Compression fitting VA 6mm 203770-8M Compression fitting VA 8mm 203770-10M Compression fitting VA 10mm 203770-12M Compression fitting VA 12mm 203770-15M Compression fitting VA 15mm 203770-18M Compression fitting VA 18mm |
|
|
|
|
| 3025 |
|
Vulkan LHR 200/200 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 200 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RH, threaded connection according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203770 G1/2RHak according to EN 560 203770-800 External thread G1/4" RHk according to EN560 203770-870 External thread G3/8" RHk according to EN 560 203770-6M Compression fitting VA 6mm 203770-8M Compression fitting VA 8mm 203770-10M Compression fitting VA 10mm 203770-12M Compression fitting VA 12mm 203770-15M Compression fitting VA 15mm 203770-18M Compression fitting VA 18mm |
|
|
|
|
| 3026 |
|
Vulkan LHR 200/200 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 200 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RH, threaded connection according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203770 G1/2RHak according to EN 560 203770-800 External thread G1/4" RHk according to EN560 203770-870 External thread G3/8" RHk according to EN 560 203770-6M Compression fitting VA 6mm 203770-8M Compression fitting VA 8mm 203770-10M Compression fitting VA 10mm 203770-12M Compression fitting VA 12mm 203770-15M Compression fitting VA 15mm 203770-18M Compression fitting VA 18mm |
|
|
|
|
| 3027 |
|
Vulkan LHR 200/200 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 200 bar adjustable, maximum output: 380 Nm³/h air at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RH, threaded connection according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 315/200 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203770 G1/2RHak according to EN 560 203770-800 External thread G1/4" RHk according to EN560 203770-870 External thread G3/8" RHk according to EN 560 203770-6M Compression fitting VA 6mm 203770-8M Compression fitting VA 8mm 203770-10M Compression fitting VA 10mm 203770-12M Compression fitting VA 12mm 203770-15M Compression fitting VA 15mm 203770-18M Compression fitting VA 18mm |
|
|
|
|
| 3028 |
|
Vulkan LHR 200/100 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RHk according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203760 G1/2RHak according to EN 560 203760-800 External thread G1/4" RHk according to EN560 203760-870 External thread G3/8" RHk according to EN 560 203760-6M Compression fitting VA 6mm 203760-8M Compression fitting VA 8mm 203760-10M Compression fitting VA 10mm 203760-12M Compression fitting VA 12mm 203760-15M Compression fitting VA 15mm 203760-18M Compression fitting VA 18mm |
|
|
|
|
| 3029 |
|
Vulkan LHR 200/100 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RHk according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203760 G1/2RHak according to EN 560 203760-800 External thread G1/4" RHk according to EN560 203760-870 External thread G3/8" RHk according to EN 560 203760-6M Compression fitting VA 6mm 203760-8M Compression fitting VA 8mm 203760-10M Compression fitting VA 10mm 203760-12M Compression fitting VA 12mm 203760-15M Compression fitting VA 15mm 203760-18M Compression fitting VA 18mm |
|
|
|
|
| 3030 |
|
Vulkan LHR 200/100 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RHk according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203760 G1/2RHak according to EN 560 203760-800 External thread G1/4" RHk according to EN560 203760-870 External thread G3/8" RHk according to EN 560 203760-6M Compression fitting VA 6mm 203760-8M Compression fitting VA 8mm 203760-10M Compression fitting VA 10mm 203760-12M Compression fitting VA 12mm 203760-15M Compression fitting VA 15mm 203760-18M Compression fitting VA 18mm |
|
|
|
|
| 3031 |
|
Vulkan LHR 200/100 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RHk according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203760 G1/2RHak according to EN 560 203760-800 External thread G1/4" RHk according to EN560 203760-870 External thread G3/8" RHk according to EN 560 203760-6M Compression fitting VA 6mm 203760-8M Compression fitting VA 8mm 203760-10M Compression fitting VA 10mm 203760-12M Compression fitting VA 12mm 203760-15M Compression fitting VA 15mm 203760-18M Compression fitting VA 18mm |
|
|
|
|
| 3032 |
|
Vulkan LHR 200/100 BSP nitrogen cylinder pressure reducer DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: 10 - 100 bar adjustable, maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet: W 24.32 x 1/14 RH U-nut according to DIN 477-1, outlet: G1/2 RHk according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 160/100 bar, width x height x depth: 180 x 140 x 190 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 203760 G1/2RHak according to EN 560 203760-800 External thread G1/4" RHk according to EN560 203760-870 External thread G3/8" RHk according to EN 560 203760-6M Compression fitting VA 6mm 203760-8M Compression fitting VA 8mm 203760-10M Compression fitting VA 10mm 203760-12M Compression fitting VA 12mm 203760-15M Compression fitting VA 15mm 203760-18M Compression fitting VA 18mm |
|
|
|
|
| 3300 |
|
Main pressure reducer Vulkan HA5/25 Acetylene 0-1.5 bar, 5 Nm?/h<br />Standards & Design:<br /><br />according to ISO 7291, single-stage design, burnout tested according to ISO 2503, with safety pressure gauges according to DIN EN ISO 5171<br />according to EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 25 bar<br />• outlet pressure<br />• Output pressure: 0-1<br />• Inlet: G3/4LHf U-nut<br />• Outlet: G1/2RHak according to EN 560<br />• Inlet pressure gauge: 0-40/25 bar<br />• Outlet pressure gauge: 0-2<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 190 x 75 mm |
|
|
|
|
| 3301 |
|
Main pressure reducer Vulkan HA10/25 Acetylene 0-1.5 bar, 10 Nm?/h<br />Standards & Design:<br /><br />according to ISO 7291, single-stage design, burnout tested according to ISO 2503, with safety pressure gauges according to DIN EN ISO 5171<br />according to EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 25 bar<br />• outlet pressure<br />• Output pressure: 0-1<br />• Inlet: G3/4LHf U-nut<br />• Outlet: G1/2RHak according to EN 560<br />• Inlet pressure gauge: 0-40/25 bar<br />• Outlet pressure gauge: 0-2<br /><br />Dimensions:<br /><br />Width x Height x Depth: 190 x 185 x 75 mm |
|
|
|
|
| 3722 |
|
Main pressure reducer Vulkan H20/300 Effect oxygen, 0-20 bar for Vareo EB/BS 60 according to DIN EN ISO 7291, single-stage design, burnout tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to DIN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 – 20 bar adjustable. Maximum output: 75 Nm³/h compressed air at 20 bar outlet pressure. Inlet: M 24x1.5 RHf U-nut. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 40/20 bar. Width x Height x Depth: 210 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for pressure control stations BS60, SE20, and EB60. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 5785 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5786 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5787 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5788 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5789 |
|
Main pressure reducer Vulkan H60/200 Effect CO2 DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 20656006 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 20656006-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 20656006-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 20656006-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 20656006-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 20656006-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 20656006-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 20656006-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 20656006-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5807 |
|
Main finned pressure reducer Vulkan HR60/200 EFFECT fuel gas, DIN 477-1, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all working conditions, with safety pressure gauges according to ISO 5171, max. inlet pressure: 200 bar, outlet pressure: 15 – 60 bar adjustable, max. output: 450 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14 LHf U-nut according to DIN 477-1, No. 1, Outlet: G1/2 RHak according to EN 560, blow-off line connection: G3/8 RHak, inlet pressure gauge: 0 – 315/200 bar, outlet pressure gauge: 0 – 100/60 bar, width x height x depth: 240 x 280 x 85 mm. Main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 204568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 204568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 204568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 204568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 204568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 204568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 204568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 204568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 204568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 204568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 204568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 204568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 204568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 204568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 204568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 204568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 204568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 204568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5819 |
|
Main pressure reducer Vulkan H20/200 Effect fuel gases 75 Nm³/h, 0 - 20 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 75 Nm³/h at 20 bar back pressure. Inlet: W21.8x1/14 LHf U-nut according to DIN 477-1. Outlet: G1/2RHak according to EN 560. Connection for relief valves G1/4RHak. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 40/20 bar. Width x Height x Depth: 200 x 190 x 75 mm. This main pressure reducer is available in, among others: following versions: Gas purity/membrane: Standard:- for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge):- for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 204520 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 204520-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 204520-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 204520-6M for technical gases up to 4.5, with Standard diaphragm compression fitting VA 6mm 204520-8M for technical gases up to 4.5, with standard diaphragm compression fitting VA 8mm 204520-10M for technical gases up to 4.5, with standard diaphragm compression fitting VA 10mm 204520-12M for technical gases up to 4.5, with standard diaphragm compression fitting VA 12mm 204520-15M for technical gases up to 4.5, with standard diaphragm compression fitting VA 15mm 204520-18M for technical gases up to 4.5, with standard diaphragm compression fitting VA 18mm 204520-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 204520-MM-800 for Pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 204520-MM-870 For pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 204520-MM-6M For pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 204520-MM-8M For pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 204520-MM-10M For pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 204520-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 204520-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 204520-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6209 |
|
Main pressure reducer Vulkan H40/300 Effect nitrogen DIN 477-5, 0 - 40 bar, 120 Nm?/h according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 40 bar adjustable. Maximum output: 120 Nm?/h at 40 bar back pressure. Inlet: W30x2RH U-nut according to DIN 477-5. Outlet connection: G1/2RHak according to EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x height x depth: 200 x 210 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 303540-800 for technical gases up to 4.5, with standard membrane external thread G1/4" RHk according to EN560 303540-870 for technical gases up to 4.5, with standard membrane external thread G3/8" RHk according to EN 560 303540-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 303540-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 303540-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 303540-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 303540-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 303540-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 303540-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 303540-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 303540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 303540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 303540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 303540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 303540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 303540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 303540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6219 |
|
Main pressure reducer Vulkan H10/300 Effect nitrogen for SE 10, 0 - 10 bar according to ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Maximum inlet pressure: 300 bar, Output pressure: 0 - 10 bar adjustable, Maximum output: 50 Nm³/h compressed air at 10 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, Outlet: G1/2 RHk U-nut according to EN 560, Inlet pressure gauge: 0 - 400/300 bar, Outlet pressure gauge: 0 - 16/10 bar, Width x Height x Depth: 210 x 190 x 75 mm *****NOTE***** Replacement pressure reducer for stationary single cylinder system SE10. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please state the system number when ordering. This main pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
| 6352 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6353 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6354 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6355 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6356 |
|
Main pressure reducer Vulkan H60/200 Effect compressed air DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: G 5/8 RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (extra charge): Item numberGas purityOutlet connection 207560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 207560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 207560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 207560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 207560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 207560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 207560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 207560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 207560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6408 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 6409 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 6410 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 6411 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 6412 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 200 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 200 bar. Output: 380 Nm³/h air at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 315/200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following, among others: Versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206770 G1/2RHak according to EN 560 206770-800 External thread G1/4" RHk according to EN560 206770-870 External thread G3/8" RHk according to EN 560 206770-6M Compression fitting VA 6mm 206770-8M Compression fitting VA 8mm 206770-10M Compression fitting VA 10mm 206770-12M Compression fitting VA 12mm 206770-15M Compression fitting VA 15mm 206770-18M Compression fitting VA 18mm |
|
|
|
|
| 6413 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 6414 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 6415 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 6416 |
|
Cylinder pressure reducer Vulkan LHR 200/100 BSP Helium DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171, Max. inlet pressure: 200 bar, Adjustable outlet pressure: 10 - 100 bar, Output: 380 Nm?/h air at 50 bar outlet pressure and 300 bar pre-pressure, Inlet: W21.8x1/14RHf U-nut according to DIN 477-1, Outlet: External thread G1/2RHak according to DIN EN 560, Inlet pressure gauge: 0 - 315/200 bar, Outlet pressure gauge: 0 - 160/100 bar, Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is suitable for, among other things, Available in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 20676026 G1/2RHak according to EN 560 20676026-800 External thread G1/4" RHk according to EN560 20676026-870 External thread G3/8" RHk according to EN 560 20676026-6M Compression fitting VA 6mm 20676026-8M Compression fitting VA 8mm 20676026-10M Compression fitting VA 10mm 20676026-12M Compression fitting VA 12mm 20676026-15M Compression fitting VA 15mm 20676026-18M compression fitting VA 18mm |
|
|
|
|
| 6418 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8 x 1/14 RH U-nut according to DIN 477-1. Outlet: G1/2 RH. Hook according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available, among others. in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206760 G1/2RHak according to EN 560 206760-800 External thread G1/4" RHk according to EN560 206760-870 External thread G3/8" RHk according to EN 560 206760-6M Compression fitting VA 6mm 206760-8M Compression fitting VA 8mm 206760-10M Compression fitting VA 10mm 206760-12M Compression fitting VA 12mm 206760-15M Compression fitting VA 15mm 206760-18M Compression fitting VA 18mm |
|
|
|
|
| 6419 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8 x 1/14 RH U-nut according to DIN 477-1. Outlet: G1/2 RH. Hook according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available, among others. in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206760 G1/2RHak according to EN 560 206760-800 External thread G1/4" RHk according to EN560 206760-870 External thread G3/8" RHk according to EN 560 206760-6M Compression fitting VA 6mm 206760-8M Compression fitting VA 8mm 206760-10M Compression fitting VA 10mm 206760-12M Compression fitting VA 12mm 206760-15M Compression fitting VA 15mm 206760-18M Compression fitting VA 18mm |
|
|
|
|
| 6420 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8 x 1/14 RH U-nut according to DIN 477-1. Outlet: G1/2 RH. Hook according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available, among others. in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206760 G1/2RHak according to EN 560 206760-800 External thread G1/4" RHk according to EN560 206760-870 External thread G3/8" RHk according to EN 560 206760-6M Compression fitting VA 6mm 206760-8M Compression fitting VA 8mm 206760-10M Compression fitting VA 10mm 206760-12M Compression fitting VA 12mm 206760-15M Compression fitting VA 15mm 206760-18M Compression fitting VA 18mm |
|
|
|
|
| 6421 |
|
Vulkan LHR 200/100 BSP cylinder pressure reducer for inert gases DIN 477-1, 10 - 100 bar according to ISO 2503, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Adjustable outlet pressure: 10 - 100 bar. Output: 380 Nm³/h (compressed air) at 50 bar outlet pressure and 200 bar inlet pressure. Inlet: W21.8 x 1/14 RH U-nut according to DIN 477-1. Outlet: G1/2 RH. Hook according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 160/100 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available, among others. in the following versions: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 206760 G1/2RHak according to EN 560 206760-800 External thread G1/4" RHk according to EN560 206760-870 External thread G3/8" RHk according to EN 560 206760-6M Compression fitting VA 6mm 206760-8M Compression fitting VA 8mm 206760-10M Compression fitting VA 10mm 206760-12M Compression fitting VA 12mm 206760-15M Compression fitting VA 15mm 206760-18M Compression fitting VA 18mm |
|
|
|
|
| 6426 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6427 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6428 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6429 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6430 |
|
Main pressure reducer Vulkan H60/200 Effect Argon DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 206560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 206560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 206560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6513 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 6514 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 6515 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 6516 |
|
Vulkan LHR 200/200 BSP cylinder pressure reducer for fuel gases DIN 477-1, 10 - 200 bar according to DIN EN ISO 2503, Class 3, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 200 bar adjustable. Maximum output: 380 Nm?/h at 50 bar outlet pressure. Inlet connection: W21.8x1/14LH U-nut according to DIN 477. Outlet connection: G1/2RHak. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 315 / 200 bar. Width x Height x Depth: 150 x 210 x 120 mm. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutput connection 204770 G1/2RHak according to EN 560 204770-800 External thread G1/4" RHk according to EN560 204770-870 External thread G3/8" RHk according to EN 560 204770-6M Compression fitting VA 6mm 204770-8M Compression fitting VA 8mm 204770-10M Compression fitting VA 10mm 204770-12M Compression fitting VA 12mm 204770-15M Compression fitting VA 15mm 204770-18M Compression fitting VA 18mm |
|
|
|
|
| 6605 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6606 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6607 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6608 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6609 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6610 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6611 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6612 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6613 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6614 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
| 6623 |
|
<p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p> |
|
|
|
|
| 6641 |
|
Main pressure reducer Vulkan H20/200 Effect Nitrogen DIN 477-1, 0 - 20 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 75 Nm?/h at 20 bar back pressure. Inlet: W 24.32 x 1/14 RHf U-nut according to DIN 477-1. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 40/20 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203520 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203520-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203520-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203520-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203520-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 203520-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 203520-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 203520-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 203520-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 203520-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203520-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203520-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203520-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203520-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203520-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203520-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203520-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203520-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6847 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|