SELECT 
  cscart_ult_product_descriptions.product_id, 
  cscart_ult_product_descriptions.short_description, 
  IF(
    cscart_ult_product_descriptions.short_description = "", 
    cscart_ult_product_descriptions.full_description, 
    ""
  ) AS full_description, 
  cscart_ult_product_descriptions.meta_keywords, 
  cscart_ult_product_descriptions.meta_description, 
  cscart_ult_product_descriptions.search_words, 
  cscart_ult_product_descriptions.promo_text 
FROM 
  cscart_ult_product_descriptions 
WHERE 
  cscart_ult_product_descriptions.product_id IN (
    3477, 3452, 3478, 3479, 3453, 3491, 3488, 
    3497, 3495, 3489, 3492, 3496, 3490, 
    3494, 6951, 3502, 3503, 3493, 3498, 
    3428, 3433, 3432, 3419, 3418
  ) 
  AND cscart_ult_product_descriptions.company_id = 1 
  AND cscart_ult_product_descriptions.lang_code = 'en'

Query time 0.00056

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "18.94"
    },
    "table": {
      "table_name": "cscart_ult_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id",
        "company_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code",
        "company_id"
      ],
      "key_length": "13",
      "rows_examined_per_scan": 24,
      "rows_produced_per_join": 24,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_ult_product_descriptions`.`company_id` = 1) and (`gaseus`.`cscart_ult_product_descriptions`.`product_id` in (3477,3452,3478,3479,3453,3491,3488,3497,3495,3489,3492,3496,3490,3494,6951,3502,3503,3493,3498,3428,3433,3432,3419,3418)) and (`gaseus`.`cscart_ult_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "16.54",
        "eval_cost": "2.40",
        "prefix_cost": "18.94",
        "data_read_per_join": "91K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "company_id",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text
3418 Vulkan L10/2 LabLine Nitrogen Line Pressure Reducer 0-10 bar, fully chrome-plated, with metal diaphragm for gas purity 5.0<br />Standards & Design:<br /><br />two-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-10 bar, maximum output: 30 Nm³/h air at 10 bar outlet pressure<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-10 bar, maximum output: 30 Nm³/h air at 10 bar outlet pressure<br />• outlet pressure: 0-10 bar, maximum output: 30 Nm³/h air at 10 bar outlet pressure<br />• output: 30 Nm³/h air at 10 bar outlet pressure<br />• Inlet: 8 mm stainless steel compression fitting<br />• Outlet: 8 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 240 x 190 x 75 mm
3419 Vulkan L10 LabLine nitrogen line pressure reducer 0-10 bar, fully chrome-plated, with metal diaphragm for gas purity 5.0<br />Standards & Design:<br /><br />single-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-10 bar, maximum output: 45 Nm³/h compressed air at 10 bar outlet pressure<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-10 bar, maximum output: 45 Nm³/h compressed air at 10 bar outlet pressure<br />• outlet pressure: 0-10 bar, maximum output: 45 Nm³/h compressed air at 10 bar outlet pressure<br />• output: 45 Nm³/h compressed air at 10 bar outlet pressure<br />• Inlet: 8 mm stainless steel compression fitting, Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-16/10 bar, width x height x depth: 200 x 190 x 75 mm<br />• Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-16/10 bar, width x height x depth: 200 x 190 x 75 mm<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 190 x 75 mm
3428 according to drawing no. 95 100 130, with inlet pressure gauge and shut-off valve,Inlet pressure max: 12 bar<br />Outlet pressure: fixed at approx. 0.5 - 0.7 bar<br />Inlet: 7/16" x 28 NS2<br />Output: compression fitting 4 mm Ms nickel-plated<br />Inlet pressure gauge: 0 - 16 bar<br />Output pressure gauge: without (no connection available)<br />With flyer provided by Linde - Linde #43586000<br />Accessory pack: bag with 3 O-rings #11207000<br /><br />Minimum order quantity 300 pieces
3432 <p>appropriate electrical equipment,marking: Ex II 1 G D [EEx ia] IIC, </p><p>to alarm and control in case of pressure drop, to connect 2 solenoid valves (230v 50Hz) and contact gauges with inductive contact, with integrated optical and acoustical signal, connection of additional external alarm possible, complete in box with potential free contact to connect contact gauges in explosive areas of group II, <br><br>box must be installed outside the explosive area, <br><br>power supply: 230V/ 50Hz</p>
3433 <p>for connecting, monitoring and switching two contact pressure gauges with inductive contacts and two solenoid valves, with internal signal display "Gas type operation OK empty" for each channel, extraction side selectable, with "Empty message hold function" (alarm must be acknowledged),Inputs: 2 x inductive contact</p><p>Output: 2 x solenoid valve 230V 50Hz<br><br>with potential-free contacts,<br><br>completely in plastic housing<br><br>Width x height x depth: 300 x 230 x 190 mm<br><br>With operating instructions, CE declaration of conformity for the electrical part, electr. Execution according to current VDE and European regulations, affixed type plate with Linde logo, glass front pane with Linde logo, Linde type designation, affixed Linde lettering, individually packed in a carton, with Linde adhesive tape</p>
3452 <p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 30 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 30 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 30 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3453 <p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3477 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 20 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3478 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape
3479 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 30 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3488 according to ISO 2503, class 3,single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3489 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3490 acc. to ISO 2503, single stage with safety gauges acc. to ISO5171inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3491 acc. to ISO 2503, class3, with high pressure compensation, single stage with safety gauges acc. to DIN ISO 5171inlet pressure max:300 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max: 48 Nm³/h at 10 bar outlet pressure<br />inlet connection: W 30x2LHk nut acc. to DIN 477-5, Nr. 57<br />outlet connection: G 3/8 LHk x 9mm tail-piece acc. to DIN EN 560<br />inlet gauge: 0 – 400 / 300 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3492 acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 300 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W30x2LH nut acc. to DIN 477-5 no. 57<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 400/300 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3493 <p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 30x2 LH nut acc. to DIN 477-5 no. 57<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3494 <p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 60 bar adjustable<br><br>flow max: 140 Nm³/h at 60 bar working pressure<br><br>inlet connection: W30x2 RHf nut acc. to DIN 477-5, no. 54<br><br>outlet connection: G 1/4RHak acc. to EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 100/60 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3495 acc. to ISO 2503, single stage with safety gauges acc. to ISO 5171inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3496 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3497 according to ISO 2503, class 3, adiabatic compression tested, single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 59<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3498 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 59<br />outlet connection: G3/4RHf male DIN 477-1, no. 9<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3502 <p>acc to ISO2503, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 – 23 Nl/min. adjustable<br><br>inlet: W 30x2 LH nut acc. to DIN 477-5<br><br>outlet: G 3/8 LHk x 9 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 400/300 bar<br><br>width x height x depth:: 210 x 230 x 75 mm</p>
3503 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 300 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape
6951 acc to EN 13918, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar<br />outlet pressure: 1,5 bar pre adjusted<br />flow: 4 – 32 Nl/min. adjustable<br />inlet: W 30x2 RH nut acc. to DIN 477-5<br />outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br />inlet gauge: 0 – 400/300 bar<br />width x height x depth:: 210 x 230 x 75 mm