| 3428 |
|
according to drawing no. 95 100 130, with inlet pressure gauge and shut-off valve,Inlet pressure max: 12 bar<br />Outlet pressure: fixed at approx. 0.5 - 0.7 bar<br />Inlet: 7/16" x 28 NS2<br />Output: compression fitting 4 mm Ms nickel-plated<br />Inlet pressure gauge: 0 - 16 bar<br />Output pressure gauge: without (no connection available)<br />With flyer provided by Linde - Linde #43586000<br />Accessory pack: bag with 3 O-rings #11207000<br /><br />Minimum order quantity 300 pieces |
|
|
|
|
|
| 3433 |
|
<p>for connecting, monitoring and switching two contact pressure gauges with inductive contacts and two solenoid valves, with internal signal display "Gas type operation OK empty" for each channel, extraction side selectable, with "Empty message hold function" (alarm must be acknowledged),Inputs: 2 x inductive contact</p><p>Output: 2 x solenoid valve 230V 50Hz<br><br>with potential-free contacts,<br><br>completely in plastic housing<br><br>Width x height x depth: 300 x 230 x 190 mm<br><br>With operating instructions, CE declaration of conformity for the electrical part, electr. Execution according to current VDE and European regulations, affixed type plate with Linde logo, glass front pane with Linde logo, Linde type designation, affixed Linde lettering, individually packed in a carton, with Linde adhesive tape</p> |
|
|
|
|
|
| 3489 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3490 |
|
acc. to ISO 2503, single stage with safety gauges acc. to ISO5171inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3492 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 300 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W30x2LH nut acc. to DIN 477-5 no. 57<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 400/300 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3493 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 30x2 LH nut acc. to DIN 477-5 no. 57<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3494 |
|
<p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 60 bar adjustable<br><br>flow max: 140 Nm³/h at 60 bar working pressure<br><br>inlet connection: W30x2 RHf nut acc. to DIN 477-5, no. 54<br><br>outlet connection: G 1/4RHak acc. to EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 100/60 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3496 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3498 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 59<br />outlet connection: G3/4RHf male DIN 477-1, no. 9<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3502 |
|
<p>acc to ISO2503, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 – 23 Nl/min. adjustable<br><br>inlet: W 30x2 LH nut acc. to DIN 477-5<br><br>outlet: G 3/8 LHk x 9 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 400/300 bar<br><br>width x height x depth:: 210 x 230 x 75 mm</p> |
|
|
|
|
|
| 3503 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 300 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape |
|
|
|
|
|
| 6951 |
|
acc to EN 13918, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar<br />outlet pressure: 1,5 bar pre adjusted<br />flow: 4 – 32 Nl/min. adjustable<br />inlet: W 30x2 RH nut acc. to DIN 477-5<br />outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br />inlet gauge: 0 – 400/300 bar<br />width x height x depth:: 210 x 230 x 75 mm |
|
|
|
|
|