Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 1172 |
|
Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4" |
|
|
|
|
|
| 1173 |
|
Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4" |
|
|
|
|
|
| 3296 |
|
<p>Vulkan F20/40 Effect SF6 (sulfur hexafluoride) cylinder pressure reducer DIN 477, 0-20 bar<br>Standards & Design:<br><br>according to ISO 2503, Class 3, with pre-pressure compensation for constant outlet pressure under all operating conditions, single-stage design, with shut-off valve, with safety gauges according to ISO 5171, maximum inlet pressure: 40 bar, outlet pressure: 0-20 bar, adjustable, maximum output: 75 Nm³/h compressed air at 20 bar outlet pressure<br>according to DIN 477-1, Outlet: G 1/4 RHk x 6 mm nozzle according to EN 560, inlet gauge: 0-60/40 bar, outlet gauge: 0-40/20 bar, width x height x depth: 210 x 190 x 75 mm<br><br>Functional elements:<br><br>• shut-off valve, with safety gauges according to ISO 5171, maximum inlet pressure: 40 bar, outlet pressure: 0-20 bar, adjustable, maximum output: 75 Nm³/h compressed air at 20 bar outlet pressure<br><br>Technical data:<br><br>• maximum inlet pressure: 40 bar, outlet pressure: 0-20 bar, adjustable, maximum output: 75 Nm³/h compressed air at 20 bar outlet pressure<br>• outlet pressure under all operating conditions, single-stage design, with shut-off valve, with safety gauges according to ISO 5171, maximum inlet pressure: 40 bar, outlet pressure: 0-20 bar, adjustable, maximum output: 75 Nm³/h compressed air at 20 bar outlet pressure<br>• output: 75 Nm³/h compressed air at 20 bar outlet pressure<br>• Inlet: W 21<br>• Outlet: G 1/4 RHk x 6 mm nozzle according to EN 560, inlet gauge: 0-60/40 bar, outlet gauge: 0-40/20 bar, width x height x depth: 210 x 190 x 75 mm<br><br>Dimensions:<br><br>width x height x depth: 210 x 190 x 75 mm</p> |
|
|
|
|
|
| 3306 |
|
<p>Vulkan F15/40 Effect SF6 (sulfur hexafluoride) cylinder pressure reducer DIN 477-1, 0-1.5 bar<br>Standards & Design:<br><br>according to ISO 2503, with pre-pressure compensation for constant outlet pressure under all operating conditions, single-stage design, with shut-off valve, with safety gauges according to ISO 5171<br>according to DIN 477-1<br>according to EN 560<br><br>Functional elements:<br><br>• shut-off valve, with safety gauges according to ISO 5171<br><br>Technical data:<br><br>• Maximum inlet pressure: 40 bar<br>• outlet pressure under all operating conditions, single-stage design, with shut-off valve, with safety gauges according to ISO 5171<br>• Output pressure: 0-1<br>• Inlet: W 21<br>• Outlet: G 1/4 RHk x 6 mm nozzle according to EN 560<br><br>Dimensions:<br><br>Width x Height x Depth: 210 x 190 x 75 mm</p> |
|
|
|
|
|
| 4917 |
|
Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4" |
|
|
|
|
|
| 4918 |
|
Vulkan F20/2 300 Effect Oxygen cylinder pressure reducer DIN 477-5, 0 - 20 bar according to ISO 2503, Class 5, two-stage design, first stage with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety gauges according to ISO 5171, with shut-off valve. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 60 Nm³/h air at 20 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5 No. 59. Outlet: G 1/4 RHk x 6mm nozzle according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 210 x 75 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This cylinder pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G1/4" RHk x 6mm Options (surcharge): Item number Gas purity Outlet connection 308230 for technical gases up to 4.5, with standard membrane Hose nozzle G1/4" RHk x 6mm 308230-812 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" RHk x 9mm 308230-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 308230-870 for technical gases up to 4.5, with standard membrane, external thread G3/8" RHk according to EN 560 308230-838 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk according to EN 560 308230-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm 308230-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm 308230-10M for technical gases up to 4.5, with standard membrane, compression fitting VA 10mm 308230-12M for technical gases up to 4.5, with standard membrane, compression fitting VA 12mm 308230-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 308230-4 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/4" 308230-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G1/4" RHk x 6mm 308230-MM-812 for pure gases up to 5.0, with metal membrane SS321 (1.4541) Hose nozzle G3/8" RHk x 9mm 308230-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308230-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308230-MM-838 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/2" RHk according to EN 560 308230-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308230-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308230-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308230-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308230-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 308230-MM-4 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/4" |
|
|
|
|
|
| 6841 |
|
<p>Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br>Standards & Design:<br><br>single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>according to DIN 477-1 No<br><br>Functional elements:<br><br>• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br><br>Technical data:<br><br>• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>• outlet pressure: 0-1<br>• output: 8 Nm³/h compressed air at 1<br>• Inlet: W24<br>• outlet: 6 mm stainless steel compression fitting<br><br>Dimensions:<br><br>Width x Height x Depth: 210 x 190 x 75 mm</p> |
|
|
|
|
|
| 6846 |
|
<p>Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br>Standards & Design:<br><br>single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>according to DIN 477-1 No<br><br>Functional elements:<br><br>• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br><br>Technical data:<br><br>• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>• outlet pressure: 0-1<br>• output: 8 Nm³/h compressed air at 1<br>• Inlet: W24<br>• outlet: 6 mm stainless steel compression fitting<br><br>Dimensions:<br><br>Width x Height x Depth: 210 x 190 x 75 mm</p> |
|
|
|
|
|
| 6962 |
|
<p>free of oil- and grease, for hydrogen and forming gas, consisting of: 2 HP shut-off valve, 2 pressure regulator H20 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), electric cable blue, length 2.000mm</p>
<p>2 solenoid valves 230VAC, <br><br>1 double non return valve and <br><br>2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate<br><br>inlet pressure max: 300 bar<br><br>outlet pressure: 15 bar fixed<br><br>flow max: 75 Nm³/h air at 15 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 300 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "H", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>with warning note:"not to use with oxygen"</p> |
|
|
|
|
|
| 6965 |
|
<p>free of oil- and grease, for oxygen,consisting of: 2 HP shut-off valve, 2 pressure regulator H40 acc to ISO 7291, single stage, adiabatic compression tested, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p>
<p>inlet pressure max: 300 bar<br><br>outlet pressure: 25 bar fixed<br><br>flow max: 125 Nm³/h air at 25 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1.095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 6966 |
|
<p>Automatic manifold Vulkan 300 bar Linde free of oil- and grease, for oxygen,consisting of: 2 HP shut-off valve, 2 pressure regulator H20 acc to ISO 7291, single stage, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p>
<p>inlet pressure max: 300 bar<br><br>outlet pressure: 15 bar fixed<br><br>flow max: 75 Nm³/h air at 15 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 300 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The product fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 6967 |
|
<p>free of oil- and grease, for MISON,consisting of: 2 HP shut-off valve, 2 pressure regulator HR20 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 20 bar fixed<br><br>flow max: 160 Nm³/h air at 20 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 475 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>with warning note:"not to use with oxygen"</p> |
|
|
|
|
|