Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 3097 |
|
Vulkan LH40 line pressure reducer nitrogen G1/2RHi both sides 0.5 - 16 bar with safety pressure gauge<br />Standards & Design:<br /><br />according to DIN EN ISO 5171, Inlet pressure: max<br /><br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 150 Nm³/h air at 16 bar outlet pressure<br />• Inlet: internal thread G1/2 RHi, Outlet: internal thread G1/2 RHi, Working pressure gauge: 0 - 16/10 bar axial, Width x Height x Depth: 90 x 180 x 90 mm<br />• Outlet: internal thread G1/2 RHi, Working pressure gauge: 0 - 16/10 bar axial, Width x Height x Depth: 90 x 180 x 90 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 90 x 180 x 90 mm |
|
|
|
|
|
| 3100 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 3103 |
|
Vulkan LH40 line pressure reducer for compressed air G1/2 RHi both sides 0.5 - 16 bar with safety pressure gauge<br />Standards & Design:<br /><br />according to DIN EN ISO 5171<br /><br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 150 Nm³/h air at 16 bar outlet pressure<br />• Inlet: internal thread G1/2 RHi<br />• Outlet: internal thread G1/2 RHi<br /><br />Dimensions:<br /><br />Width x Height x Depth: 90 x 180 x 90 mm |
|
|
|
|
|
| 3106 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 3114 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 3120 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 3125 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 3153 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 3154 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 3412 |
|
Vulkan L15/2 LabLine Nitrogen Line Pressure Reducer 0-1.5 bar, fully chrome-plated, with metal diaphragm for gas purity 5.0<br />Standards & Design:<br /><br />two-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h air at 1<br />• Inlet: 8 mm stainless steel compression fitting, Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br />• Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br /><br />Dimensions:<br /><br />width x height x depth: 240 x 190 x 75 mm |
|
|
|
|
|
| 6672 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 6688 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 6689 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 6694 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 6702 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 6706 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 6708 |
|
Line pressure reducer Vulkan LH25/10 oxygen 0.5 - 10 bar with safety pressure gauge ISO 5171, Max. inlet pressure: 40 bar<br />Technical data:<br /><br />• Outlet pressure: 0<br />• output: 180 Nm?/h compressed air at 10 bar outlet pressure, Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Inlet: Internal thread G1RH, Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br />• Outlet: Internal thread G1RH, Output pressure gauge: 0-16/10 axial, Width x Height x Depth: 200 x 210 x 120 mm<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 210 x 120 mm |
|
|
|
|
|
| 6724 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
|
| 6725 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
|
| 6726 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
|
| 6937 |
|
Vulkan L15/2 LabLine Nitrogen Line Pressure Reducer 0-1.5 bar, fully chrome-plated, with metal diaphragm for gas purity 5.0<br />Standards & Design:<br /><br />two-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h air at 1<br />• Inlet: 8 mm stainless steel compression fitting, Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br />• Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br /><br />Dimensions:<br /><br />width x height x depth: 240 x 190 x 75 mm |
|
|
|
|
|
| 6939 |
|
Vulkan L15/2 LabLine Nitrogen Line Pressure Reducer 0-1.5 bar, fully chrome-plated, with metal diaphragm for gas purity 5.0<br />Standards & Design:<br /><br />two-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h air at 1<br />• Inlet: 8 mm stainless steel compression fitting, Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br />• Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br /><br />Dimensions:<br /><br />width x height x depth: 240 x 190 x 75 mm |
|
|
|
|
|
| 6943 |
|
Vulkan L15/2 LabLine Nitrogen Line Pressure Reducer 0-1.5 bar, fully chrome-plated, with metal diaphragm for gas purity 5.0<br />Standards & Design:<br /><br />two-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h air at 1<br />• Inlet: 8 mm stainless steel compression fitting, Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br />• Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br /><br />Dimensions:<br /><br />width x height x depth: 240 x 190 x 75 mm |
|
|
|
|
|
| 6944 |
|
Vulkan L15 LabLine Nitrogen Line Pressure Reducer 0-1.5 bar, fully chrome-plated, with metal diaphragm for gas purity 5.0<br />Standards & Design:<br /><br />single-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: 8 mm stainless steel compression fitting, Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br />• Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-2<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 190 x 75 mm |
|
|
|
|
|