SELECT 
  cscart_ult_product_descriptions.product_id, 
  cscart_ult_product_descriptions.short_description, 
  IF(
    cscart_ult_product_descriptions.short_description = "", 
    cscart_ult_product_descriptions.full_description, 
    ""
  ) AS full_description, 
  cscart_ult_product_descriptions.meta_keywords, 
  cscart_ult_product_descriptions.meta_description, 
  cscart_ult_product_descriptions.search_words, 
  cscart_ult_product_descriptions.promo_text 
FROM 
  cscart_ult_product_descriptions 
WHERE 
  cscart_ult_product_descriptions.product_id IN (
    3723, 5194, 5195, 5196, 5197, 1429, 1430, 
    1431, 1432, 3161, 3719, 3720, 5142, 
    5143, 5144, 6730, 6731, 3158, 3159, 
    3160, 2102, 2039, 1985, 1472, 1484, 
    5613, 1428, 1478, 1466, 1873, 1460, 
    1449, 3743, 1454, 1444, 1422, 1765, 
    3734, 1418, 3136, 2040, 2041, 2042, 
    2043, 2044, 2045, 2046, 2047
  ) 
  AND cscart_ult_product_descriptions.company_id = 1 
  AND cscart_ult_product_descriptions.lang_code = 'en'

Query time 0.00109

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "37.86"
    },
    "table": {
      "table_name": "cscart_ult_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id",
        "company_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code",
        "company_id"
      ],
      "key_length": "13",
      "rows_examined_per_scan": 48,
      "rows_produced_per_join": 48,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_ult_product_descriptions`.`company_id` = 1) and (`gaseus`.`cscart_ult_product_descriptions`.`product_id` in (3723,5194,5195,5196,5197,1429,1430,1431,1432,3161,3719,3720,5142,5143,5144,6730,6731,3158,3159,3160,2102,2039,1985,1472,1484,5613,1428,1478,1466,1873,1460,1449,3743,1454,1444,1422,1765,3734,1418,3136,2040,2041,2042,2043,2044,2045,2046,2047)) and (`gaseus`.`cscart_ult_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "33.06",
        "eval_cost": "4.80",
        "prefix_cost": "37.86",
        "data_read_per_join": "183K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "company_id",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text
1418 Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
1422 Main fin pressure reducer Vulkan HR40/300 EFFECT inert gas, for EB/BS 100/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 – 40 bar adjustable, max. output: 290 Nm³/h air at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary EB100 single-bundle systems and BS100 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
1428 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1429 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
1430 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
1431 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
1432 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
1444 Main ribbed pressure reducer Vulkan HR40/300 Effect Inert Gas, AM55/300, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1449 Main ribbed pressure reducer Vulkan HR40/200 Effect Inert Gas, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1454 Main ribbed pressure reducer Vulkan HR40/300 Effect Inert Gas, AM55/300, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1460 Main ribbed pressure reducer Vulkan HR40/200 Effect Oxygen, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety pressure gauges according to ISO 5171, with metal diaphragm. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K, and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1466 Main ribbed pressure reducer Vulkan HR20/300 Effect Oxygen AM 45 right according to ISO 7291, single-stage design, burnout safety tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: fixed at 20 bar, maximum output: 170 Nm³/h compressed air at 20 bar outlet pressure. Inlet: M 24x1.5 RHak -16S, Outlet: G 1/2 RHk U-nut according to EN 560, input pressure gauge: 0 – 315/200 bar, output pressure gauge: 0 – 40/20 bar, width x height x depth: 240 x 240 x 85 mm *****NOTE***** Replacement pressure reducer for automatic changeover groups AM45, 45K and 45KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1472 <p>Main ribbed pressure reducer Vulkan HR20/200 Effect Oxygen AM 45 right according to ISO 7291, single-stage design, burnout safety tested according to ISO 7291, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: fixed at 20 bar, maximum output: 170 Nm³/h compressed air at 20 bar back pressure. Inlet: M 24x1.5 RHak -16S, Outlet: G 1/2 RHk U-nut according to EN 560, inlet pressure gauge: 0 – 315/200 bar, outlet pressure gauge: 0 – 40/20 bar, width x height x depth: 240 x 240 x 85 mm *****NOTE***** Replacement pressure reducer for automatic changeover groups AM45, 45K and 45KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).</p>
1478 Main ribbed pressure reducer Vulkan HR20/300 Effect Oxygen AM 45 left according to ISO 7291, single-stage design, burnout safety tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: fixed at 20 bar, maximum output: 170 Nm³/h compressed air at 20 bar outlet pressure. Inlet: M 24x1.5 RHak -16S, Outlet: G 1/2 RHk U-nut according to EN 560, inlet pressure gauge: 0 – 315/200 bar, outlet pressure gauge: 0 – 40/20 bar, width x height x depth: 240 x 240 x 85 mm *****NOTE***** Replacement pressure reducer for automatic changeover groups AM45, 45K and 45KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1484 <p>Main ribbed pressure reducer Vulkan HR20/200 EFFECT oxygen, 0-20 bar, 170 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all working conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 170 Nm?/h compressed air at 20 bar back pressure. Inlet: G3/4 RHf U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is Available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208527 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208527-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208527-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208527-6M for technical gases up to 4.5, with standard membrane compression fitting VA 6mm 208527-8M for technical gases up to 4.5, with standard membrane compression fitting VA 8mm 208527-10M for technical gases up to 4.5, with standard membrane compression fitting VA 10mm 208527-12M for technical gases up to 4.5, with standard membrane compression fitting VA 12mm 208527-15M for technical gases up to 4.5, with standard membrane compression fitting VA 15mm 208527-18M for technical gases up to 4.5, with standard membrane compression fitting VA 18mm 208527-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208527-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208527-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208527-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208527-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208527-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 208527-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 208527-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 208527-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm</p>
1765 Main ribbed pressure reducer Vulkan HR60/200 EFFECT inert gas, DIN 477-1, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, with safety gauges according to ISO 5171, max. inlet pressure: 200 bar, outlet pressure: 15 – 60 bar adjustable, max. output: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1, No. 6, Outlet: G1/2 RHak according to EN 560, inlet pressure gauge: 0 – 315/200 bar, outlet pressure gauge: 0 – 100/60 bar, width x height x depth: 240 x 280 x 85 mm. This main pressure reducer is available in the following, among others: Versions: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 206568 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 206568-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 206568-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 206568-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 206568-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 206568-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 206568-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 206568-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 206568-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 206568-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 206568-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 206568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 206568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 206568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
1873 Main finned pressure reducer Vulkan HR40/200 EFFECT inert gas, DIN 477-1, 15-40 bar according to ISO 7291, single-stage design, burn-out tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure under all working conditions, with safety pressure gauges according to ISO 5171, max. inlet pressure: 200 bar, outlet pressure: 15 - 40 bar, adjustable, max. output: 290 Nm³/h compressed air at 40 bar outlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1, No. 6, outlet: G1/2 RHak according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 60/40 bar, width x height x depth: 240 x 280 x 85 mm. Main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 206546 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 206546-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 206546-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 206546-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 206546-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 206546-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 206546-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 206546-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 206546-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 206546-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 206546-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 206546-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 206546-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 206546-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206546-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206546-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206546-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206546-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
1985 <p>Main ribbed pressure reducer Vulkan HR20/200 EFFECT oxygen, 0-20 bar, 170 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all working conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 170 Nm?/h compressed air at 20 bar back pressure. Inlet: G3/4 RHf U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is Available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208527 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208527-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208527-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208527-6M for technical gases up to 4.5, with standard membrane compression fitting VA 6mm 208527-8M for technical gases up to 4.5, with standard membrane compression fitting VA 8mm 208527-10M for technical gases up to 4.5, with standard membrane compression fitting VA 10mm 208527-12M for technical gases up to 4.5, with standard membrane compression fitting VA 12mm 208527-15M for technical gases up to 4.5, with standard membrane compression fitting VA 15mm 208527-18M for technical gases up to 4.5, with standard membrane compression fitting VA 18mm 208527-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208527-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208527-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208527-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208527-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208527-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 208527-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 208527-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 208527-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm</p>
2039 Main ribbed pressure reducer Vulkan HR10/300 EFFECT oxygen, 0 - 10 bar according to ISO 7291, burnout tested according to ISO 7291, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm³/h compressed air at 10 bar outlet pressure. Inlet: W 30x2 RHf U-nut according to DIN 477-5, No. 59. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 308518 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 308518-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 308518-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 308518-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 308518-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 308518-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 308518-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 308518-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 308518-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 308518-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 308518-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 308518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2040 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2041 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2042 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2043 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2044 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2045 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2046 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2047 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2102 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
3136 Main ribbed pressure reducer Vulkan HR40/200-MM-SV Effect nitrogen DIN477-1, 15-40 bar, 290 Nm?/h<br />Standards & Design:<br /><br />according to ISO 7291, with metal diaphragm for gas purity up to 5<br />single-stage design, with safety gauges according to DIN EN ISO 5171, Inlet pressure max: 200 bar, Outlet pressure: 15 - 40 bar adjustable, Output max: 290 Nm?/h compressed air at 40 bar outlet pressure<br />according to DIN 477-1, Outlet: G1/2RHak according to EN 560, Inlet gauge: 0 - 315/200 bar, Outlet gauge: 0 - 60/40 bar, Width x Height x Depth: 240 x 330 x 85 mm With mounted Pressure relief/flush valve on 60° outlet #412037, handwheel (star grip) - PA, outlet (side): G1/8 RHif<br /><br />Technical data:<br /><br />• Outlet pressure: 15 - 40 bar adjustable, Output max: 290 Nm?/h compressed air at 40 bar outlet pressure<br />• Output max: 290 Nm?/h compressed air at 40 bar outlet pressure<br />• Inlet: W 24, 32 x 1/14 RH U-nut according to DIN 477-1, Outlet: G1/2RHak according to EN 560, Inlet gauge: 0 - 315/200 bar, Outlet gauge: 0 - 60/40 bar, Width x Height x Depth: 240 x 330 x 85 mm With mounted Pressure relief/flush valve on 60° outlet #412037, handwheel (star grip) - PA, outlet (side): G1/8 RHif<br />• Outlet: G1/2RHak according to EN 560, Inlet gauge: 0 - 315/200 bar, Outlet gauge: 0 - 60/40 bar, Width x Height x Depth: 240 x 330 x 85 mm With mounted Pressure relief/flush valve on 60° outlet #412037, handwheel (star grip) - PA, outlet (side): G1/8 RHif<br /><br />Dimensions:<br /><br />Width x Height x Depth: 240 x 330 x 85 mm With mounted Pressure relief/flush valve on 60° outlet #412037, handwheel (star grip) - PA, outlet (side): G1/8 RHif
3158 Main pressure reducer Vulkan H60/300 Effect oxygen, 0-60 bar for Vareo EB/BS 75<br />Standards & Design:<br /><br />according to ISO 7291, single-stage design, with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• output: 140 Nm?/h at 40 bar back pressure<br />• Inlet: M24x1<br />• outlet: G1/2RHk U-nut according to DIN EN 560<br />• Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar<br />• outlet pressure gauge: 0 - 100/60 bar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 190 x 75 mm
3159 Main pressure reducer Vulkan H60/300 Effect oxygen, 0-60 bar for Vareo EB/BS 75<br />Standards & Design:<br /><br />according to ISO 7291, single-stage design, with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• output: 140 Nm?/h at 40 bar back pressure<br />• Inlet: M24x1<br />• outlet: G1/2RHk U-nut according to DIN EN 560<br />• Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar<br />• outlet pressure gauge: 0 - 100/60 bar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 190 x 75 mm
3160 Main pressure reducer Vulkan H60/300 Effect oxygen, 0-60 bar for Vareo EB/BS 75<br />Standards & Design:<br /><br />according to ISO 7291, single-stage design, with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• output: 140 Nm?/h at 40 bar back pressure<br />• Inlet: M24x1<br />• outlet: G1/2RHk U-nut according to DIN EN 560<br />• Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar<br />• outlet pressure gauge: 0 - 100/60 bar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 190 x 75 mm
3161 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
3719 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
3720 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
3723 Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 right according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
3734 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
3743 Main finned pressure reducer Vulkan HR40/300 EFFECT inert gas DIN 477-5, 15-40 bar according to ISO 7291, single-stage design, burn-out tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure under all operating conditions, with safety gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 15 – 40 bar adjustable. Maximum output: 290 Nm³/h compressed air at 40 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G1/2 RHak according to EN 560. Inlet gauge: 0 – 400/300 bar. Outlet gauge: 0 – 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306546 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306546-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306546-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306546-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306546-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306546-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306546-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306546-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306546-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306546-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306546-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306546-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306546-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306546-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306546-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306546-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306546-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306546-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5142 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
5143 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
5144 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
5194 Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 right according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
5195 Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 right according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
5196 Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 right according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
5197 Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 right according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
5613 Main ribbed pressure reducer Vulkan HR20/300 EFFECT oxygen DIN 477-5, 0 - 20 bar according to ISO 7291, burn-out tested according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, with safety gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 170 Nm³/h compressed air at 20 bar back pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477-5, No. 59. Outlet: G1/2 RHak according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 240 x 85 mm. Important note for 300 bar pressure reducers. - Please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 308527 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 308527-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 308527-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 308527-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 308527-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 308527-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 308527-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 308527-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 308527-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 308527-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 308527-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308527-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308527-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308527-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308527-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308527-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308527-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 308527-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
6730 Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm
6731 Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm