SELECT 
  cscart_seo_names.object_id AS product_id, 
  cscart_seo_names.name AS seo_name, 
  cscart_seo_names.path AS seo_path 
FROM 
  cscart_seo_names 
WHERE 
  cscart_seo_names.object_id IN (
    3038, 3039, 3040, 3041, 3042, 3043, 3044, 
    3045, 3853, 5790, 5791, 5792, 5793, 
    5794, 5795, 5796, 5797, 5798, 6307, 
    6308, 6309, 6310, 6311, 6357
  ) 
  AND cscart_seo_names.type = "p" 
  AND cscart_seo_names.dispatch = "" 
  AND cscart_seo_names.lang_code = 'en' 
  AND (
    cscart_seo_names.company_id = 1 
    OR cscart_seo_names.company_id = 0
  )

Query time 0.00056

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "33.61"
    },
    "table": {
      "table_name": "cscart_seo_names",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "dispatch"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "object_id",
        "type",
        "dispatch",
        "lang_code",
        "company_id"
      ],
      "key_length": "210",
      "rows_examined_per_scan": 48,
      "rows_produced_per_join": 48,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_seo_names`.`object_id` in (3038,3039,3040,3041,3042,3043,3044,3045,3853,5790,5791,5792,5793,5794,5795,5796,5797,5798,6307,6308,6309,6310,6311,6357)) and (`gaseus`.`cscart_seo_names`.`type` = 'p') and (`gaseus`.`cscart_seo_names`.`dispatch` = '') and (`gaseus`.`cscart_seo_names`.`lang_code` = 'en') and ((`gaseus`.`cscart_seo_names`.`company_id` = 1) or (`gaseus`.`cscart_seo_names`.`company_id` = 0)))",
      "cost_info": {
        "read_cost": "28.81",
        "eval_cost": "4.80",
        "prefix_cost": "33.61",
        "data_read_per_join": "81K"
      },
      "used_columns": [
        "name",
        "object_id",
        "company_id",
        "type",
        "dispatch",
        "path",
        "lang_code"
      ]
    }
  }
}

Result

product_id seo_name seo_path
3038 main-regulator-nitrogen-0-40-bar-vulkan-h40-200-effect-en-15-en 265/266/271/308
3039 main-regulator-nitrogen-0-40-bar-vulkan-h40-200-effect-en-13-en 265/266/271/308
3040 main-regulator-fuel-gas-0-40-bar-vulkan-h40-200-effect-en-11-en 265/266/271/308
3041 main-regulator-nitrogen-0-40-bar-vulkan-h40-200-effect-en-9-en 265/266/271/308
3042 main-regulator-nitrogen-0-40-bar-vulkan-h40-200-effect-en-7-en 265/266/271/308
3043 main-regulator-nitrogen-0-40-bar-vulkan-h40-200-effect-en-5-en 265/266/271/308
3044 main-regulator-nitrogen-0-40-bar-vulkan-h40-200-effect-en-3-en 265/266/271/308
3045 main-regulator-nitrogen-0-40-bar-vulkan-h40-200-effect-en-en 265/266/271/308
3853 main-regulator-argon-0-40-bar-vulkan-h40-200-effect-en-18 265/266/271/308
5790 main-regulator-nitrogen-0-40-bar-vulkan-h40-200-effect-en-11-en 265/266/271/308
5791 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-14-en 265/266/271/308
5792 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-12-en 265/266/271/308
5793 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-10-en 265/266/271/308
5794 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-8-en 265/266/271/308
5795 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-6-en 265/266/271/308
5796 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-4-en 265/266/271/308
5797 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-2-en 265/266/271/308
5798 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-18 265/266/271/308
6307 main-regulator-oxygen-0-40-bar-vulkan-h40-200-effect-en-8-en 265/266/271/308
6308 main-regulator-oxygen-0-40-bar-vulkan-h40-200-effect-en-6-en 265/266/271/308
6309 main-regulator-oxygen-0-40-bar-vulkan-h40-200-effect-en-4-en 265/266/271/308
6310 main-regulator-co-0-40-bar-vulkan-h40-200-effect-en-11-en 265/266/271/308
6311 main-regulator-oxygen-0-40-bar-vulkan-h40-200-effect-en-9 265/266/271/308
6357 main-regulator-oxygen-0-40-bar-vulkan-h40-200-effect-en-7-en 265/266/271/308