Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
| 515 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
| 1654 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1655 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1656 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1657 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1658 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1659 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1660 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1661 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1662 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1663 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1664 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1665 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1666 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1667 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1668 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1669 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1670 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 1671 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 2220 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 2221 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 2222 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 2223 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 3156 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
| 3676 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
| 5131 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
| 5353 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 5354 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 5355 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 5356 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 5357 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 5358 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 5400 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5401 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5402 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5403 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5404 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5405 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5406 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5407 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5408 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5409 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5410 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5411 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5412 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5413 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5414 |
|
Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 6728 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|