SELECT 
  cscart_product_descriptions.product_id, 
  cscart_product_descriptions.short_description, 
  IF(
    cscart_product_descriptions.short_description = '' 
    OR cscart_product_descriptions.short_description IS NULL, 
    cscart_product_descriptions.full_description, 
    ''
  ) AS full_description, 
  cscart_product_descriptions.meta_keywords, 
  cscart_product_descriptions.meta_description, 
  cscart_product_descriptions.search_words, 
  cscart_product_descriptions.promo_text, 
  cscart_product_descriptions.unit_name 
FROM 
  cscart_product_descriptions 
WHERE 
  cscart_product_descriptions.product_id IN (
    5400, 5401, 5402, 5403, 5404, 5405, 5406, 
    5407, 5408, 5409, 5410, 5411, 5412, 
    5413, 5414, 6728, 515, 3156, 3676, 5131, 
    1654, 1655, 1656, 1657, 1658, 1659, 
    1660, 1661, 1662, 1663, 1664, 1665, 
    1666, 1667, 1668, 1669, 1670, 1671, 
    2220, 2221, 2222, 2223, 5353, 5354, 
    5355, 5356, 5357, 5358
  ) 
  AND cscart_product_descriptions.lang_code = 'en'

Query time 0.00080

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "57.81"
    },
    "table": {
      "table_name": "cscart_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code"
      ],
      "key_length": "9",
      "rows_examined_per_scan": 48,
      "rows_produced_per_join": 48,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_product_descriptions`.`product_id` in (5400,5401,5402,5403,5404,5405,5406,5407,5408,5409,5410,5411,5412,5413,5414,6728,515,3156,3676,5131,1654,1655,1656,1657,1658,1659,1660,1661,1662,1663,1664,1665,1666,1667,1668,1669,1670,1671,2220,2221,2222,2223,5353,5354,5355,5356,5357,5358)) and (`gaseus`.`cscart_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "53.01",
        "eval_cost": "4.80",
        "prefix_cost": "57.81",
        "data_read_per_join": "219K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text",
        "unit_name"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text unit_name
515 Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
1654 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1655 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1656 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1657 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1658 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1659 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1660 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1661 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1662 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1663 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1664 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1665 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1666 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1667 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1668 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1669 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1670 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
1671 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
2220 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
2221 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
2222 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
2223 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
3156 Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
3676 Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
5131 Main ribbed pressure reducer Vulkan HR60/300 EFFECT oxygen, for EB/BS 120/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 - 60 bar adjustable, max. output: 450 Nm³/h air at 60 bar outlet pressure, inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary Single bundle systems EB120 and base stations BS120. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541).
5353 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
5354 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
5355 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
5356 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
5357 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
5358 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
5400 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5401 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5402 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5403 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5404 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5405 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5406 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5407 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5408 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5409 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5410 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5411 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5412 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5413 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
5414 Main ribbed pressure reducer Vulkan HR60/300 EFFECT inert gas, DIN 477-5, 15-60 bar according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety gauges according to ISO 5171. Inlet pressure max: 300 bar. Outlet pressure: 15 – 60 bar adjustable. Output max: 450 Nm³/h compressed air at 60 bar back pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0 – 400/300 bar. Outlet pressure gauge: 0 – 100/60 bar. Width x Height x Depth: 240 x 330 x 85 mm. Important note for 300 bar pressure reducers - please check your Cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306568 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306568-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306568-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306568-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306568-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306568-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306568-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306568-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306568-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306568-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306568-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306568-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306568-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306568-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306568-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306568-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306568-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306568-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
6728 Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm