Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 1433 |
|
Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541). |
|
|
|
|
|
| 1489 |
|
Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 right according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
|
| 1499 |
|
Main pressure reducer Vulkan H40/300 Effect Inert Gas for AM 40/300 left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: fixed at 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M 24x1.5 RHak, outlet: G 1/2 RHk, U-nut according to EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 200 x 190 x 75 mm. *****NOTE*****Replacement pressure reducer for automatic changeover group AM40 / AM35 (28 bar) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane SS321 (1.4541). |
|
|
|
|
|
| 2268 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
|
| 2269 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
|
| 2270 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
|
| 2271 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
|
| 2336 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
|
| 2337 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
|
| 2338 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
|
| 2339 |
|
Main pressure reducer Vulkan H60/300 Effect nitrogen DIN 477-5, 0-60 bar, 140 Nm³/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 300 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm³/h compressed air at 60 bar back pressure. Inlet: W30x2RHf U-nut according to DIN 477-5, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-400/300 bar. Outlet pressure gauge: 0-100/60 bar. Width x height x depth: 210 x 190 x 75 mm. Important note for 300 bar pressure reducers - please check your bottle connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 303560 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) G1/2RHak according to EN 560 303560-800 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G1/4" RHk according to EN560 303560-870 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) External thread G3/8" RHk according to EN 560 303560-6M for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) Compression fitting VA 6mm 303560-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 8mm 303560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 303560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 303560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 303560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm |
|
|
|
|
|
| 6614 |
|
<p>Cylinder pressure reducer Vulkan F15/2 200 test gases DIN 477-1, 0 - 1.5 bar according to DIN EN ISO 2503, Class 3, two-stage design, TÜV type-tested in accordance with Pressure Equipment Directive 97/23/EC, with safety pressure gauges according to DIN EN ISO 5171, with shut-off valve. Maximum inlet pressure: 200 bar. Output pressure: 0 - 1.5 bar adjustable. Maximum output: 8 Nm³/h air at 1.5 bar outlet pressure. Inlet: M19x1.5LH U-nut according to DIN 477-1 No. 14. Outlet: G3/8LHk x 9mm nozzle according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 2.5 / 1.5 bar. Width x Height x Depth: 240 x 190 x 75 mm This cylinder pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - hose nozzle G3/8" LHk x 9mm Options (surcharge): Order number Gas purity/membrane Outlet screw connection 203851 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 9mm 203851-815 for technical gases up to 4.5, with standard membrane Hose nozzle G3/8" LHk x 6mm 203851-814 for technical gases up to 4.5, with standard membrane External thread G3/8" LHk according to EN 560 203851-838 for technical gases up to 4.5, with standard membrane External thread G1/2" LHk according to EN 560 203851-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203851-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203851-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203851-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203851-2 for technical gases up to 4.5, with standard membrane Compression fitting VA 1/8" 203851-4 for technical gases up to 4.5, with Standard diaphragm compression fitting VA 1/4" 203851-MM-815 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 6mm 203851-MM for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) hose nozzle G3/8" LHk x 9mm 203851-MM-814 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G3/8" LHk according to EN 560 203851-MM-838 for pure gases up to 5.0, with metal diaphragm SS321 (1.4541) external thread G1/2" LHk according to EN 560 203851-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203851-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203851-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203851-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203851-MM-2 for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 1/8" 203851-MM-4 for pure gases up to 5.0, with Metal membrane SS321 (1.4541) compression fitting VA 1/4"</p> |
|
|
|
|
|