Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 1516 |
|
Main pressure reducer Vulkan H20/200 Effect Oxygen right for AM35/AM35H according to DIN EN ISO 7291, single-stage design, burnout tested according to ISO 7291, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 20 bar fixed. Maximum output: 75 Nm³/h at 20 bar back pressure. Inlet: external thread M24x1.5RHak-16S, Outlet: union nut G1/2RHk according to DIN EN 560. Inlet pressure gauge: 0 - 315 / 200 bar. Outlet pressure gauge: 0 - 40 / 20 bar. Width x Height x Depth: 210 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for automatic changeover group AM35/AM35H (20 bar fixed) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm SS321 (1.4541). |
|
|
|
|
|
| 2189 |
|
<p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p> |
|
|
|
|
|
| 2190 |
|
<p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p> |
|
|
|
|
|
| 2191 |
|
<p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p> |
|
|
|
|
|
| 2192 |
|
<p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p> |
|
|
|
|
|
| 2193 |
|
<p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p> |
|
|
|
|
|
| 2194 |
|
<p>Main pressure reducer Vulkan H40/200 Effect Nitrogen DIN 477-1, 0-40 bar, 120 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-40 bar adjustable. Maximum output: 120 Nm?/h compressed air at 40 bar back pressure. Inlet: W24.32x1/14RHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/40 bar. Width x Height x Depth: 200 x 210 x 75 mm. This main pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 203540 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 203540-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 203540-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 203540-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 203540-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 203540-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 203540-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 203540-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 203540-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 203540-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 203540-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 203540-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 203540-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 203540-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 203540-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 203540-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 203540-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 203540-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm</p> |
|
|
|
|
|
| 2941 |
|
Main pressure reducer Vulkan H60/200 Effect Hydrogen DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14LHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 204560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 204560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 204560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 204560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 204560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 204560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 204560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 204560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 204560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
|
| 6522 |
|
Main pressure reducer Vulkan H60/200 Effect Hydrogen DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14LHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 204560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 204560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 204560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 204560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 204560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 204560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 204560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 204560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 204560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
|
| 6523 |
|
Main pressure reducer Vulkan H60/200 Effect Hydrogen DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14LHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 204560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 204560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 204560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 204560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 204560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 204560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 204560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 204560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 204560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
|
| 6524 |
|
Main pressure reducer Vulkan H60/200 Effect Hydrogen DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14LHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 204560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 204560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 204560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 204560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 204560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 204560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 204560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 204560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 204560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
|
| 6525 |
|
Main pressure reducer Vulkan H60/200 Effect Hydrogen DIN 477-1, 0-60 bar, 140 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN 562. Maximum inlet pressure: 200 bar. Output pressure: 0-60 bar adjustable. Maximum output: 140 Nm?/h compressed air at 60 bar back pressure. Inlet: W21.8x1/14LHf U-nut according to DIN 477, Outlet: G 1/2 RHak according to DIN EN 560. Inlet pressure gauge: 0-315/200 bar. Outlet pressure gauge: 0-100/60 bar. Width x Height x Depth: 210 x 190 x 75 mm. This main pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberGas purityOutlet connection 204560 for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 204560-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G1/4" RHk according to EN560 204560-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) External thread G3/8" RHk according to EN 560 204560-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 6mm 204560-8M for pure Gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 204560-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 204560-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 204560-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 204560-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
|