Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
| 1422 |
|
Main fin pressure reducer Vulkan HR40/300 EFFECT inert gas, for EB/BS 100/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, max. inlet pressure: 300 bar, outlet pressure: 15 – 40 bar adjustable, max. output: 290 Nm³/h air at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 – 400/300 bar, outlet pressure gauge: 0 – 60/40 bar, width x height x depth: 240 x 280 x 85 mm *****NOTE***** Replacement pressure reducer for stationary EB100 single-bundle systems and BS100 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541). |
|
|
|
|
| 1428 |
|
Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 1444 |
|
Main ribbed pressure reducer Vulkan HR40/300 Effect Inert Gas, AM55/300, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 1449 |
|
Main ribbed pressure reducer Vulkan HR40/200 Effect Inert Gas, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 1454 |
|
Main ribbed pressure reducer Vulkan HR40/300 Effect Inert Gas, AM55/300, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 1460 |
|
Main ribbed pressure reducer Vulkan HR40/200 Effect Oxygen, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety pressure gauges according to ISO 5171, with metal diaphragm. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K, and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 1466 |
|
Main ribbed pressure reducer Vulkan HR20/300 Effect Oxygen AM 45 right according to ISO 7291, single-stage design, burnout safety tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: fixed at 20 bar, maximum output: 170 Nm³/h compressed air at 20 bar outlet pressure. Inlet: M 24x1.5 RHak -16S, Outlet: G 1/2 RHk U-nut according to EN 560, input pressure gauge: 0 – 315/200 bar, output pressure gauge: 0 – 40/20 bar, width x height x depth: 240 x 240 x 85 mm *****NOTE***** Replacement pressure reducer for automatic changeover groups AM45, 45K and 45KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 1478 |
|
Main ribbed pressure reducer Vulkan HR20/300 Effect Oxygen AM 45 left according to ISO 7291, single-stage design, burnout safety tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: fixed at 20 bar, maximum output: 170 Nm³/h compressed air at 20 bar outlet pressure. Inlet: M 24x1.5 RHak -16S, Outlet: G 1/2 RHk U-nut according to EN 560, inlet pressure gauge: 0 – 315/200 bar, outlet pressure gauge: 0 – 40/20 bar, width x height x depth: 240 x 240 x 85 mm *****NOTE***** Replacement pressure reducer for automatic changeover groups AM45, 45K and 45KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541). |
|
|
|
|
| 1484 |
|
<p>Main ribbed pressure reducer Vulkan HR20/200 EFFECT oxygen, 0-20 bar, 170 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all working conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 170 Nm?/h compressed air at 20 bar back pressure. Inlet: G3/4 RHf U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is Available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208527 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208527-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208527-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208527-6M for technical gases up to 4.5, with standard membrane compression fitting VA 6mm 208527-8M for technical gases up to 4.5, with standard membrane compression fitting VA 8mm 208527-10M for technical gases up to 4.5, with standard membrane compression fitting VA 10mm 208527-12M for technical gases up to 4.5, with standard membrane compression fitting VA 12mm 208527-15M for technical gases up to 4.5, with standard membrane compression fitting VA 15mm 208527-18M for technical gases up to 4.5, with standard membrane compression fitting VA 18mm 208527-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208527-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208527-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208527-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208527-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208527-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 208527-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 208527-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 208527-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm</p> |
|
|
|
|
| 1873 |
|
Main finned pressure reducer Vulkan HR40/200 EFFECT inert gas, DIN 477-1, 15-40 bar according to ISO 7291, single-stage design, burn-out tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure under all working conditions, with safety pressure gauges according to ISO 5171, max. inlet pressure: 200 bar, outlet pressure: 15 - 40 bar, adjustable, max. output: 290 Nm³/h compressed air at 40 bar outlet pressure. Inlet: W21.8x1/14 RHf U-nut according to DIN 477-1, No. 6, outlet: G1/2 RHak according to EN 560, inlet pressure gauge: 0 - 315/200 bar, outlet pressure gauge: 0 - 60/40 bar, width x height x depth: 240 x 280 x 85 mm. Main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 206546 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 206546-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 206546-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 206546-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 206546-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 206546-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 206546-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 206546-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 206546-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 206546-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 206546-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 206546-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 206546-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 206546-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 206546-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 206546-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 206546-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 206546-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 3743 |
|
Main finned pressure reducer Vulkan HR40/300 EFFECT inert gas DIN 477-5, 15-40 bar according to ISO 7291, single-stage design, burn-out tested according to ISO 7291, with pre-pressure compensation for constant outlet pressure under all operating conditions, with safety gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 15 – 40 bar adjustable. Maximum output: 290 Nm³/h compressed air at 40 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5, No. 54. Outlet: G1/2 RHak according to EN 560. Inlet gauge: 0 – 400/300 bar. Outlet gauge: 0 – 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. Important note for 300 bar. Pressure reducers - Please check your cylinder connection! Cylinder pressure reducers for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure reducers. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 306546 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 306546-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 306546-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 306546-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 306546-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 306546-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 306546-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 306546-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 306546-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 306546-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 306546-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 306546-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 306546-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 306546-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 306546-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 306546-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 306546-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 306546-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|
| 5613 |
|
Main ribbed pressure reducer Vulkan HR20/300 EFFECT oxygen DIN 477-5, 0 - 20 bar according to ISO 7291, burn-out tested according to ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, with safety gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 170 Nm³/h compressed air at 20 bar back pressure. Inlet: W 30 x 2 RH U-nut according to DIN 477-5, No. 59. Outlet: G1/2 RHak according to EN 560. Inlet gauge: 0 - 400/300 bar. Outlet gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 240 x 85 mm. Important note for 300 bar pressure reducers. - Please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 308527 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 308527-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 308527-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 308527-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 308527-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 308527-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 308527-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 308527-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 308527-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 308527-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 308527-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308527-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308527-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308527-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308527-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308527-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308527-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 308527-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm |
|
|
|
|