SELECT 
  cscart_product_descriptions.product_id, 
  cscart_product_descriptions.short_description, 
  IF(
    cscart_product_descriptions.short_description = '' 
    OR cscart_product_descriptions.short_description IS NULL, 
    cscart_product_descriptions.full_description, 
    ''
  ) AS full_description, 
  cscart_product_descriptions.meta_keywords, 
  cscart_product_descriptions.meta_description, 
  cscart_product_descriptions.search_words, 
  cscart_product_descriptions.promo_text, 
  cscart_product_descriptions.unit_name 
FROM 
  cscart_product_descriptions 
WHERE 
  cscart_product_descriptions.product_id IN (
    5142, 5143, 5144, 6730, 6731, 3158, 3159, 
    3160, 2102, 2039, 1985, 1472
  ) 
  AND cscart_product_descriptions.lang_code = 'en'

Query time 0.00044

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "14.46"
    },
    "table": {
      "table_name": "cscart_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code"
      ],
      "key_length": "9",
      "rows_examined_per_scan": 12,
      "rows_produced_per_join": 12,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_product_descriptions`.`product_id` in (5142,5143,5144,6730,6731,3158,3159,3160,2102,2039,1985,1472)) and (`gaseus`.`cscart_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "13.26",
        "eval_cost": "1.20",
        "prefix_cost": "14.46",
        "data_read_per_join": "54K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text",
        "unit_name"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text unit_name
1472 <p>Main ribbed pressure reducer Vulkan HR20/200 Effect Oxygen AM 45 right according to ISO 7291, single-stage design, burnout safety tested according to ISO 7291, with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, maximum inlet pressure: 200 bar, outlet pressure: fixed at 20 bar, maximum output: 170 Nm³/h compressed air at 20 bar back pressure. Inlet: M 24x1.5 RHak -16S, Outlet: G 1/2 RHk U-nut according to EN 560, inlet pressure gauge: 0 – 315/200 bar, outlet pressure gauge: 0 – 40/20 bar, width x height x depth: 240 x 240 x 85 mm *****NOTE***** Replacement pressure reducer for automatic changeover groups AM45, 45K and 45KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).</p>
1985 <p>Main ribbed pressure reducer Vulkan HR20/200 EFFECT oxygen, 0-20 bar, 170 Nm?/h according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all working conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 20 bar adjustable. Maximum output: 170 Nm?/h compressed air at 20 bar back pressure. Inlet: G3/4 RHf U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 40/20 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is Available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208527 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208527-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208527-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208527-6M for technical gases up to 4.5, with standard membrane compression fitting VA 6mm 208527-8M for technical gases up to 4.5, with standard membrane compression fitting VA 8mm 208527-10M for technical gases up to 4.5, with standard membrane compression fitting VA 10mm 208527-12M for technical gases up to 4.5, with standard membrane compression fitting VA 12mm 208527-15M for technical gases up to 4.5, with standard membrane compression fitting VA 15mm 208527-18M for technical gases up to 4.5, with standard membrane compression fitting VA 18mm 208527-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208527-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208527-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208527-MM-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208527-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208527-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 10mm 208527-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 12mm 208527-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 15mm 208527-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) Compression fitting VA 18mm</p>
2039 Main ribbed pressure reducer Vulkan HR10/300 EFFECT oxygen, 0 - 10 bar according to ISO 7291, burnout tested according to ISO 7291, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm³/h compressed air at 10 bar outlet pressure. Inlet: W 30x2 RHf U-nut according to DIN 477-5, No. 59. Outlet: G1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel diaphragm SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 308518 for technical gases up to 4.5, with standard diaphragm G1/2RHak according to EN 560 308518-800 for technical gases up to 4.5, with standard diaphragm external thread G1/4" RHk according to EN560 308518-870 for technical gases up to 4.5, with standard diaphragm external thread G3/8" RHk according to EN 560 308518-6M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 6mm 308518-8M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 8mm 308518-10M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 10mm 308518-12M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 12mm 308518-15M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 15mm 308518-18M for technical gases up to 4.5, with standard membrane, compression fitting made of stainless steel 18mm 308518-MM for pure gases up to 5.0, with metal membrane made of SS321 (1.4541) G1/2RHak according to EN 560 308518-MM-800 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 308518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 308518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 308518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 308518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 308518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 308518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 308518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
2102 Main ribbed pressure reducer Vulkan HR10/200 EFFECT oxygen, 0 - 10 bar according to DIN EN ISO 7291, single-stage design, with pre-pressure compensation for constant back pressure under all operating conditions, burnout tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 0 - 10 bar adjustable. Maximum output: 90 Nm?/h at 10 bar back pressure. Inlet: G 3/4 RH U-nut according to DIN 477-1, No. 9. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 240 x 240 x 85 mm. This main ribbed pressure reducer is available in the following versions, among others: Gas purity/membrane: Standard: - for technical gases up to a gas purity of 4.5 with standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - G1/2RHak according to EN 560 Options (surcharge): Item number Gas purity Outlet connection 208518 for technical gases up to 4.5, with standard membrane G1/2RHak according to EN 560 208518-800 for technical gases up to 4.5, with standard membrane External thread G1/4" RHk according to EN560 208518-870 for technical gases up to 4.5, with standard membrane External thread G3/8" RHk according to EN 560 208518-6M for technical gases up to 4.5, with standard membrane Compression fitting VA 6mm 208518-8M for technical gases up to 4.5, with standard membrane Compression fitting VA 8mm 208518-10M for technical gases up to 4.5, with standard membrane Compression fitting VA 10mm 208518-12M for technical gases up to 4.5, with standard membrane Compression fitting VA 12mm 208518-15M for technical gases up to 4.5, with standard membrane Compression fitting VA 15mm 208518-18M for technical gases up to 4.5, with standard membrane Compression fitting VA 18mm 208518-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) G1/2RHak according to EN 560 208518-MM-800 for pure Gases up to 5.0, with metal membrane SS321 (1.4541) external thread G1/4" RHk according to EN560 208518-MM-870 for pure gases up to 5.0, with metal membrane SS321 (1.4541) external thread G3/8" RHk according to EN 560 208518-MM-6M ​​for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 6mm 208518-MM-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 8mm 208518-MM-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 10mm 208518-MM-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 12mm 208518-MM-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 15mm 208518-MM-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) compression fitting VA 18mm
3158 Main pressure reducer Vulkan H60/300 Effect oxygen, 0-60 bar for Vareo EB/BS 75<br />Standards & Design:<br /><br />according to ISO 7291, single-stage design, with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• output: 140 Nm?/h at 40 bar back pressure<br />• Inlet: M24x1<br />• outlet: G1/2RHk U-nut according to DIN EN 560<br />• Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar<br />• outlet pressure gauge: 0 - 100/60 bar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 190 x 75 mm
3159 Main pressure reducer Vulkan H60/300 Effect oxygen, 0-60 bar for Vareo EB/BS 75<br />Standards & Design:<br /><br />according to ISO 7291, single-stage design, with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• output: 140 Nm?/h at 40 bar back pressure<br />• Inlet: M24x1<br />• outlet: G1/2RHk U-nut according to DIN EN 560<br />• Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar<br />• outlet pressure gauge: 0 - 100/60 bar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 190 x 75 mm
3160 Main pressure reducer Vulkan H60/300 Effect oxygen, 0-60 bar for Vareo EB/BS 75<br />Standards & Design:<br /><br />according to ISO 7291, single-stage design, with metal diaphragm, with pre-pressure compensation for constant back pressure with falling back pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• outlet pressure: adjustable 0 - 60 bar, maximum output: 140 Nm?/h at 40 bar back pressure<br />• output: 140 Nm?/h at 40 bar back pressure<br />• Inlet: M24x1<br />• outlet: G1/2RHk U-nut according to DIN EN 560<br />• Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 100/60 bar<br />• outlet pressure gauge: 0 - 100/60 bar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 190 x 75 mm
5142 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
5143 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
5144 Main pressure reducer Vulkan H40/300 Effect Inert Gas, 0-40 bar for Vareo EB/BS 70 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, with safety pressure gauges according to ISO 5171, burnout tested according to ISO 7291, maximum inlet pressure: 300 bar, outlet pressure: adjustable 0 - 40 bar, maximum output: 120 Nm³/h at 40 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 200 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems. EB70 and BS70 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard membrane. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel membrane made of SS321 (1.4541).
6730 Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm
6731 Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm