SELECT 
  cscart_ult_product_descriptions.product_id, 
  cscart_ult_product_descriptions.short_description, 
  IF(
    cscart_ult_product_descriptions.short_description = "", 
    cscart_ult_product_descriptions.full_description, 
    ""
  ) AS full_description, 
  cscart_ult_product_descriptions.meta_keywords, 
  cscart_ult_product_descriptions.meta_description, 
  cscart_ult_product_descriptions.search_words, 
  cscart_ult_product_descriptions.promo_text 
FROM 
  cscart_ult_product_descriptions 
WHERE 
  cscart_ult_product_descriptions.product_id IN (
    4093, 3122, 6675, 6696, 6703, 3118, 3111, 
    3124, 3112, 324, 3419, 6704
  ) 
  AND cscart_ult_product_descriptions.company_id = 1 
  AND cscart_ult_product_descriptions.lang_code = 'en'

Query time 0.00044

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "9.47"
    },
    "table": {
      "table_name": "cscart_ult_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id",
        "company_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code",
        "company_id"
      ],
      "key_length": "13",
      "rows_examined_per_scan": 12,
      "rows_produced_per_join": 12,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_ult_product_descriptions`.`company_id` = 1) and (`gaseus`.`cscart_ult_product_descriptions`.`product_id` in (4093,3122,6675,6696,6703,3118,3111,3124,3112,324,3419,6704)) and (`gaseus`.`cscart_ult_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "8.27",
        "eval_cost": "1.20",
        "prefix_cost": "9.47",
        "data_read_per_join": "45K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "company_id",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text
324 <p>Vulkan L10 line pressure reducer for compressed air G1/2RH both sides, 0-10 bar, based on ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0-10 bar, adjustable. Maximum output: 45 Nm³/h at 10 bar outlet pressure. Inlet: G1/2RHak according to EN 560. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-40/20 bar. Outlet pressure gauge: 0-16/10 bar. Width x Height x Depth: 210 x 190 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm. Optional (Surcharge):- for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order numberGas purity/membraneInlet/outlet screw connection 107529 for technical gases up to 4.5, with standard membrane on both sides. external thread G1/2" RHk according to EN 560 107529-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 107529-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 107529-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107529-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107529-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107529-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107529-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107529-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107529-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107529-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107529-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107529-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107529-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p>
3111 In-line dome pressure reducer Vulkan LD1 MD Helium G1RHi, 0.5 - 99 bar, both sides, not for carbon dioxide. Material: Brass/Viton<br />Standards & Design:<br /><br />Single-stage design<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 100 bar<br />• outlet pressure<br />• Output pressure: 0<br />• Inlet: Internal thread G1RHi<br />• Outlet: Internal thread G1RHi<br /><br />Dimensions:<br /><br />Width x Height x Depth: 130 x 170 x 130 mm
3112 Line dome pressure reducer Vulkan LD1 MD inert gases G1RHi both sides. 0.5 - 99 bar not for carbon dioxide, material: brass / Viton<br />Standards & Design:<br /><br />single-stage design, maximum inlet pressure: 100 bar, output pressure: 0<br /><br />Technical data:<br /><br />• maximum inlet pressure: 100 bar, output pressure: 0<br />• outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: without, output pressure gauge: without, width x height x depth: 130 x 170 x 130 mm<br />• output pressure: 0<br /><br />Dimensions:<br /><br />width x height x depth: 130 x 170 x 130 mm
3118 Line pressure reducer Vulkan LP216 Helium G1/4RHi, 1 - 250 mbar<br />Standards & Design:<br /><br />single-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 21 bar, output pressure: 1 - 250 mbar, adjustable<br /><br />Technical data:<br /><br />• maximum inlet pressure: 21 bar, output pressure: 1 - 250 mbar, adjustable<br />• output pressure: 1 - 250 mbar, adjustable<br />• Inlet: internal thread G1/4RHi, output: internal thread G1/4RHi, output gauge: 0 - 250 mbar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 108 x 162 x 108 mm
3122 Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm
3124 In-line dome pressure reducer Vulkan LD1 MD hydrogen G1RHi, both sides 0.5 - 99 bar. Materials: Brass<br />Standards & Design:<br /><br />single-stage design, maximum inlet pressure: 100 bar<br /><br />Technical data:<br /><br />• maximum inlet pressure: 100 bar<br />• outlet pressure<br />• Output pressure: 0<br />• Inlet: internal thread G1RHi, outlet: internal thread G1RHi<br />• outlet: internal thread G1RHi<br /><br />Dimensions:<br /><br />Width x Height x Depth: 130 x 170 x 130 mm
3419 Vulkan L10 LabLine nitrogen line pressure reducer 0-10 bar, fully chrome-plated, with metal diaphragm for gas purity 5.0<br />Standards & Design:<br /><br />single-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-10 bar, maximum output: 45 Nm³/h compressed air at 10 bar outlet pressure<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, adjustable outlet pressure: 0-10 bar, maximum output: 45 Nm³/h compressed air at 10 bar outlet pressure<br />• outlet pressure: 0-10 bar, maximum output: 45 Nm³/h compressed air at 10 bar outlet pressure<br />• output: 45 Nm³/h compressed air at 10 bar outlet pressure<br />• Inlet: 8 mm stainless steel compression fitting, Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-16/10 bar, width x height x depth: 200 x 190 x 75 mm<br />• Outlet: 8 mm stainless steel compression fitting, input pressure gauge: 0-40/20 bar, output pressure gauge: 0-16/10 bar, width x height x depth: 200 x 190 x 75 mm<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 190 x 75 mm
4093 <p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p>
6675 Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm
6696 Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm
6703 Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm
6704 <p>Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br>Standards & Design:<br><br>single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br>according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br><br>Technical data:<br><br>• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br>• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br>• output pressure: 0 to 1<br><br>Dimensions:<br><br>width x height x depth: 200 x 200 x 75 mm</p>