SELECT 
  cscart_ult_product_descriptions.product_id, 
  cscart_ult_product_descriptions.short_description, 
  IF(
    cscart_ult_product_descriptions.short_description = "", 
    cscart_ult_product_descriptions.full_description, 
    ""
  ) AS full_description, 
  cscart_ult_product_descriptions.meta_keywords, 
  cscart_ult_product_descriptions.meta_description, 
  cscart_ult_product_descriptions.search_words, 
  cscart_ult_product_descriptions.promo_text 
FROM 
  cscart_ult_product_descriptions 
WHERE 
  cscart_ult_product_descriptions.product_id IN (
    1426, 1427, 5136, 5137, 5138, 5139, 5140, 
    5141, 6711, 1455, 5164, 1445, 5154, 
    1456, 5165, 1446, 5155, 1458, 5167, 
    1448, 5157, 1459, 5168, 5158
  ) 
  AND cscart_ult_product_descriptions.company_id = 1 
  AND cscart_ult_product_descriptions.lang_code = 'en'

Query time 0.00052

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "18.94"
    },
    "table": {
      "table_name": "cscart_ult_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id",
        "company_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code",
        "company_id"
      ],
      "key_length": "13",
      "rows_examined_per_scan": 24,
      "rows_produced_per_join": 24,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_ult_product_descriptions`.`company_id` = 1) and (`gaseus`.`cscart_ult_product_descriptions`.`product_id` in (1426,1427,5136,5137,5138,5139,5140,5141,6711,1455,5164,1445,5154,1456,5165,1446,5155,1458,5167,1448,5157,1459,5168,5158)) and (`gaseus`.`cscart_ult_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "16.54",
        "eval_cost": "2.40",
        "prefix_cost": "18.94",
        "data_read_per_join": "91K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "company_id",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text
1426 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1427 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1445 Main ribbed pressure reducer Vulkan HR40/200 Effect compressed air, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1446 Main ribbed pressure reducer Vulkan HR40/200 Effect fuel gas, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1448 Main ribbed pressure reducer Vulkan HR40/200 Effect Helium, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1455 Main ribbed pressure reducer Vulkan HR40/200 Effect compressed air, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1456 Main ribbed pressure reducer Vulkan HR40/200 Effect fuel gas, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1458 Main ribbed pressure reducer Vulkan HR40/200 Effect Helium, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
1459 Main ribbed pressure reducer Vulkan HR40/200 Effect Inert Gas, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5136 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5137 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5138 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5139 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5140 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5141 Main fin pressure reducer Vulkan HR20/300 EFFECT oxygen, for EB/BS 80/300 according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171, maximum inlet pressure: 300 bar, outlet pressure: 0 - 20 bar adjustable, maximum output: 170 Nm³/h air at 20 bar outlet pressure. Inlet: M24x1.5 RHf U-nut, outlet: G1/2 RHk U-nut according to DIN EN 560, inlet pressure gauge: 0 - 400/300 bar, outlet pressure gauge: 0 - 40/20 bar, width x height x depth: 240 x 240 x 85 mm. *****NOTE***** Replacement pressure reducer for stationary single-bundle systems EB80 and BS80 base stations. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5154 Main ribbed pressure reducer Vulkan HR40/200 Effect compressed air, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5155 Main ribbed pressure reducer Vulkan HR40/200 Effect fuel gas, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5157 Main ribbed pressure reducer Vulkan HR40/200 Effect Helium, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5158 Main ribbed pressure reducer Vulkan HR40/200 Effect Inert Gas, AM55/200, right side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5164 Main ribbed pressure reducer Vulkan HR40/200 Effect compressed air, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5165 Main ribbed pressure reducer Vulkan HR40/200 Effect fuel gas, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5167 Main ribbed pressure reducer Vulkan HR40/200 Effect Helium, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
5168 Main ribbed pressure reducer Vulkan HR40/200 Effect Inert Gas, AM55/200, left side according to ISO 7291, single-stage design, with pre-pressure compensation for constant outlet pressure with falling pre-pressure, burnout safety tested according to ISO 7291, with safety gauges according to ISO 5171. Maximum inlet pressure: 200 bar. Output pressure: 28 bar fixed. Maximum output: 250 Nm³/h air at 28 bar outlet pressure. Inlet: M24x1.5 RHak - 16 S Vareo. Outlet: G 1/2 RHk U-nut according to DIN EN 560. Inlet pressure gauge: 0 - 315/200 bar. Outlet pressure gauge: 0 - 60/40 bar. Width x Height x Depth: 240 x 280 x 85 mm. *****NOTE***** Replacement pressure reducer for automatic changeover groups AM55, 55K and 55KM. This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main ribbed pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm made of SS321 (1.4541).
6711 Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm