SELECT 
  cscart_product_descriptions.product_id, 
  cscart_product_descriptions.short_description, 
  IF(
    cscart_product_descriptions.short_description = '' 
    OR cscart_product_descriptions.short_description IS NULL, 
    cscart_product_descriptions.full_description, 
    ''
  ) AS full_description, 
  cscart_product_descriptions.meta_keywords, 
  cscart_product_descriptions.meta_description, 
  cscart_product_descriptions.search_words, 
  cscart_product_descriptions.promo_text, 
  cscart_product_descriptions.unit_name 
FROM 
  cscart_product_descriptions 
WHERE 
  cscart_product_descriptions.product_id IN (
    5822, 5823, 12916, 12921, 12956, 12958, 
    13014, 13028, 13040, 13052, 12960, 
    12974
  ) 
  AND cscart_product_descriptions.lang_code = 'en'

Query time 0.00051

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "14.46"
    },
    "table": {
      "table_name": "cscart_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code"
      ],
      "key_length": "9",
      "rows_examined_per_scan": 12,
      "rows_produced_per_join": 12,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_product_descriptions`.`product_id` in (5822,5823,12916,12921,12956,12958,13014,13028,13040,13052,12960,12974)) and (`gaseus`.`cscart_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "13.26",
        "eval_cost": "1.20",
        "prefix_cost": "14.46",
        "data_read_per_join": "54K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text",
        "unit_name"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text unit_name
5822 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
5823 Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm
12916 Ribbed tapping point regulator Vulkan TecLine ER20, single stage. Brass body, stainless steel diaphragm, PTFE seals. Gas purity up to 4.5. Safety gauges acc. to DIN EN ISO 5171. Inlet pressure max 100 bar. Outlet pressure 0–20 bar (adjustable). Inlet: G 1/2 RH (right-hand) nut acc. to EN 560. Outlet: G 1/2 RH x 9 mm hose nozzle. Dimensions: 180 × 225 × 75 mm, weight 1.7 kg.
12921 Ribbed tapping point regulator Vulkan TecLine ER40, single stage. Brass body, stainless steel diaphragm, PTFE seals. Gas purity up to 4.5. Safety gauges acc. to DIN EN ISO 5171. Inlet pressure max 100 bar. Outlet pressure 15–40 bar (adjustable). Inlet: G 1/2 RH (right-hand) nut acc. to EN 560. Outlet: G 1/2 RH x 9 mm hose nozzle. Dimensions: 180 × 225 × 75 mm, weight 1.7 kg.
12956 Single-bundle acetylene manifold station Vulkan TecLine EB10 (with standard gauges). Complete on stainless steel base plate, acc. to ISO 14114, with HA10 regulator acc. to ISO 7291, automatic quick cut-off valve acc. to ISO 15615, flashback arrestor acc. to ISO 5175, and main shut-off valve. Manual switching. Inlet pressure max 26 bar, outlet pressure 0–1.5 bar. Max. flow 10 Nm³/h at 1.5 bar. Dimensions: 700 × 190 × 160 mm, 14 kg.
12958 Single-bundle acetylene manifold station Vulkan TecLine EB20 (with standard gauges). Complete on stainless steel base plate, acc. to ISO 14114, with HA10/H20 regulator acc. to ISO 7291, automatic quick cut-off valve acc. to ISO 15615, flashback arrestor acc. to ISO 5175, and main shut-off valve. Manual switching. Inlet pressure max 26 bar, outlet pressure 0–1.5 bar. Max. flow 18 Nm³/h at 1.5 bar. Dimensions: 970 × 190 × 160 mm, 16 kg.
12960 Single-bundle manifold station Vulkan TecLine EB60/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator H20 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 75 Nm³/h at 20 bar. With standard pressure gauges. Dimensions: 420 × 320 × 110 mm, 5.0 kg.
12974 Single-bundle manifold station Vulkan TecLine EB70/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR40 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–40 bar. Max. flow 120 Nm³/h at 40 bar. With standard pressure gauges. Dimensions: N/A mm, N/A kg.
13014 Single-bundle manifold station Vulkan TecLine EB100/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR40 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–40 bar. Max. flow 290 Nm³/h at 40 bar. With standard pressure gauges. Dimensions: 440 × 370 × 130 mm, N/A kg.
13028 Single-bundle manifold station Vulkan TecLine EB120/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR60 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–60 bar. Max. flow 450 Nm³/h at 60 bar. With standard pressure gauges. Dimensions: N/A mm, N/A kg.
13040 Single-bundle manifold station Vulkan TecLine EB200/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR200 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–200 bar. Max. flow 480 Nm³/h at 200 bar. With standard pressure gauges. Dimensions: 390 × 240 × 240 mm, N/A kg.
13052 Single-bundle manifold station Vulkan TecLine EB270/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR270 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–270 bar. Max. flow 480 Nm³/h at 270 bar. With standard pressure gauges. Dimensions: 390 × 240 × 240 mm, N/A kg.