Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
| 5822 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 5823 |
|
Pressure reducer Vulkan LHR 300/270 inert gas DIN 477-5, 10 - 270 bar BSP according to ISO 2503, single-stage design, with safety pressure gauges according to ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 10 - 270 bar adjustable. Maximum output: 380 Nm³/h compressed air at 50 bar outlet pressure. Inlet: W 30x2 RH U-nut according to DIN 477-5. Outlet: G 1/2 RHak according to EN 560. Inlet pressure gauge: 0 - 400 / 300 bar. Outlet pressure gauge: 0 - 400 / 300 bar. Width x height x depth: 150 x 210 x 120 mm. Important note for 300 bar pressure reducers - please check your cylinder connection! Cylinder pressure regulators for 300 bar have a manual connection according to DIN 477 Part 5 and are NOT backward compatible. This means they do NOT fit cylinders with a maximum filling pressure of 200 bar! If necessary, see our following tutorial, 3: Difference between 200 bar and 300 bar pressure regulators. This main and line pressure reducer is available in the following versions, among others: Special outlet screw connection: Standard:- G1/2RHak according to EN 560 Options (surcharge): Item numberOutlet connection 306711 G1/2RHak according to EN 560 306711-800 External thread G1/4" RHk according to EN560 306711-870 External thread G3/8" RHk according to EN 560 306711-6M Compression fitting VA 6mm 306711-8M Compression fitting VA 8mm 306711-10M Compression fitting VA 10mm 306711-12M Compression fitting VA 12mm 306711-15M Compression fitting VA 15mm 306711-18M compression fitting VA 18mm |
|
|
|
|
| 12956 |
|
Single-bundle acetylene manifold station Vulkan TecLine EB10 (with standard gauges). Complete on stainless steel base plate, acc. to ISO 14114, with HA10 regulator acc. to ISO 7291, automatic quick cut-off valve acc. to ISO 15615, flashback arrestor acc. to ISO 5175, and main shut-off valve. Manual switching. Inlet pressure max 26 bar, outlet pressure 0–1.5 bar. Max. flow 10 Nm³/h at 1.5 bar. Dimensions: 700 × 190 × 160 mm, 14 kg. |
|
|
|
|
| 12958 |
|
Single-bundle acetylene manifold station Vulkan TecLine EB20 (with standard gauges). Complete on stainless steel base plate, acc. to ISO 14114, with HA10/H20 regulator acc. to ISO 7291, automatic quick cut-off valve acc. to ISO 15615, flashback arrestor acc. to ISO 5175, and main shut-off valve. Manual switching. Inlet pressure max 26 bar, outlet pressure 0–1.5 bar. Max. flow 18 Nm³/h at 1.5 bar. Dimensions: 970 × 190 × 160 mm, 16 kg. |
|
|
|
|
| 13028 |
|
Single-bundle manifold station Vulkan TecLine EB120/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR60 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–60 bar. Max. flow 450 Nm³/h at 60 bar. With standard pressure gauges. Dimensions: N/A mm, N/A kg. |
|
|
|
|
| 13040 |
|
Single-bundle manifold station Vulkan TecLine EB200/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR200 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–200 bar. Max. flow 480 Nm³/h at 200 bar. With standard pressure gauges. Dimensions: 390 × 240 × 240 mm, N/A kg. |
|
|
|
|
| 13052 |
|
Single-bundle manifold station Vulkan TecLine EB270/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR270 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–270 bar. Max. flow 480 Nm³/h at 270 bar. With standard pressure gauges. Dimensions: 390 × 240 × 240 mm, N/A kg. |
|
|
|
|