SELECT 
  cscart_product_descriptions.product_id, 
  cscart_product_descriptions.short_description, 
  IF(
    cscart_product_descriptions.short_description = '' 
    OR cscart_product_descriptions.short_description IS NULL, 
    cscart_product_descriptions.full_description, 
    ''
  ) AS full_description, 
  cscart_product_descriptions.meta_keywords, 
  cscart_product_descriptions.meta_description, 
  cscart_product_descriptions.search_words, 
  cscart_product_descriptions.promo_text, 
  cscart_product_descriptions.unit_name 
FROM 
  cscart_product_descriptions 
WHERE 
  cscart_product_descriptions.product_id IN (
    12988, 13000, 13148, 13153, 12928, 12926, 
    12942, 3135, 12850, 12869, 12876, 12896
  ) 
  AND cscart_product_descriptions.lang_code = 'en'

Query time 0.00048

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "14.46"
    },
    "table": {
      "table_name": "cscart_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code"
      ],
      "key_length": "9",
      "rows_examined_per_scan": 12,
      "rows_produced_per_join": 12,
      "filtered": "100.00",
      "index_condition": "((`gaseus`.`cscart_product_descriptions`.`product_id` in (12988,13000,13148,13153,12928,12926,12942,3135,12850,12869,12876,12896)) and (`gaseus`.`cscart_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "13.26",
        "eval_cost": "1.20",
        "prefix_cost": "14.46",
        "data_read_per_join": "54K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text",
        "unit_name"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text unit_name
3135 HD bundle hose Vulkan Vareo 200 bar, DN 6, PN 200 Flexible metal corrugated hose with two anti-kink springs, vent valve (attached to the hose on the bundle side) and safety cable (with loop on the bundle side) for connecting a nitrogen cylinder bundle to a gas supply Vareo, length 2,000 mm, DN6, PN 200, inlet according to DIN 477-1, No. 10, outlet M 24x1.5 RHk U-nut -16S Vareo
12850 Tapping point regulator Vulkan LabLine E10, single stage. Chrome-plated brass body, stainless steel diaphragm, EPDM seals. Gas purity up to 5.0. Safety gauges acc. to DIN EN ISO 5171. Leakage rate 1×10⁻⁶ mbar·l/s. Inlet pressure max 20 bar. Outlet pressure 0–10 bar (adjustable). Max. flow 40 Nm³/h at 10 bar back pressure. Inlet: G 3/8 RH (right-hand) nut acc. to EN 560. Outlet: stainless steel clamp ring fitting 6 mm. LP gauge: 0–16 bar. Dimensions: 120 × 180 × 65 mm, weight 1.0 kg.
12869 Tapping point regulator Vulkan LabLine E10F for oxygen, single stage with integrated flowmeter and regulating valve for precise flow control. Chrome-plated brass body, stainless steel diaphragm, EPDM seals. Gas purity up to 5.0. Leakage rate 1×10⁻⁶ mbar·l/s. Inlet pressure max 200 bar. Outlet pressure 5.0 bar (fixed). Flow range 1.0–15.0 Nl/min (adjustable). Inlet: G 3/8 RH (right-hand) nut acc. to EN 560. Outlet: stainless steel clamp ring fitting 6 mm. Dimensions: 120 × 220 × 65 mm, weight 1.0 kg.
12876 Tapping point regulator Vulkan TecLine E10, single stage. Brass body, Perbunan diaphragm and seals. Gas purity up to 4.5. Safety gauges acc. to DIN EN ISO 5171. Inlet pressure max 20 bar. Outlet pressure 0–10 bar (adjustable). Max. flow 46 Nm³/h at 10 bar back pressure. Inlet: G 3/8 RH (right-hand) nut acc. to EN 560. Outlet: G 1/4 RH x 6 mm hose nozzle. LP gauge: 0–16 bar. Dimensions: 120 × 160 × 65 mm, weight 1.0 kg.
12896 Tapping point regulator Vulkan TecLine E10F, single stage with integrated flowmeter for precise flow control. Brass body, Perbunan diaphragm and seals, acc. to ISO 2503 Class 10. Inlet pressure max 20 bar. Outlet pressure 4.5 bar (fixed). Flowmeter range 0.5–5.0 Nl/min (adjustable). Inlet: G 3/8 RH (right-hand) nut acc. to EN 560. Outlet: G 1/4 RH x 6 mm hose nozzle. Dimensions: 120 × 210 × 65 mm, weight 1.0 kg.
12926 Single-cylinder manifold station Vulkan TecLine SE10/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator H10 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–10 bar adjustable. Max. flow 50 Nm³/h at 10 bar. With standard pressure gauges. Dimensions: 420 × 260 × 110 mm, 4.5 kg.
12928 Single-cylinder manifold station Vulkan LabLine SE 10/300 Effect (with standard gauges), chrome-plated. Modular add-on system. Manual switching. Complete on stainless steel base plate: 1× HP shut-off valve, 1× manifold regulator H10 single stage acc. to ISO 7291, 1× main shut-off valve, 1× purge valve, 1× cylinder rack. Inlet max 300 bar, outlet 0–10 bar. Max. flow 50 Nm³/h at 10 bar. Stainless steel diaphragm, gas purity up to 5.0. Dimensions: 420 × 280 × 110 mm.
12942 Single-cylinder manifold station Vulkan TecLine SE20/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator H20 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–20 bar adjustable. Max. flow 75 Nm³/h at 20 bar. With standard pressure gauges. Dimensions: 420 × 320 × 110 mm, 5.0 kg.
12988 Single-bundle manifold station Vulkan TecLine EB75/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR60 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–60 bar. Max. flow 140 Nm³/h at 60 bar. With standard pressure gauges. Dimensions: 370 × 280 × 110 mm, N/A kg.
13000 Single-bundle manifold station Vulkan TecLine EB80/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR20 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 170 Nm³/h at 20 bar. With standard pressure gauges. Dimensions: 440 × 350 × 130 mm, N/A kg.
13148 Single-cylinder manifold station Vulkan LabLine SE 10/2 300 (with standard gauges), chrome-plated. Modular add-on system. Manual switching. Complete on stainless steel base plate: 1× HP shut-off valve, 1× manifold regulator H10/2 double stage acc. to ISO 7291, 1× main shut-off valve, 1× purge valve, 1× cylinder rack. Inlet max 300 bar, outlet 0–10 bar. Max. flow 30 Nm³/h at 10 bar. Stainless steel diaphragm, gas purity up to 5.0. Dimensions: 480 × 280 × 110 mm.
13153 Single-cylinder manifold station Vulkan LabLine SE 10/2 300 (with contact gauge (Reed switch)), chrome-plated. Modular add-on system. Manual switching. Complete on stainless steel base plate: 1× HP shut-off valve, 1× manifold regulator H10/2 double stage acc. to ISO 7291, 1× main shut-off valve, 1× purge valve, 1× cylinder rack. Inlet max 300 bar, outlet 0–10 bar. Max. flow 30 Nm³/h at 10 bar. Stainless steel diaphragm, gas purity up to 5.0. Dimensions: 480 × 280 × 110 mm.