acc to DIN EN ISO 2503, class 3, double stage, with safety gauges acc. to DIN ISO 5171
inlet pressure max: 200 bar
outlet pressure: 0 – 10 bar adjustable
flow max: 28 Nm³/h air at 10 bar outlet pressure
inlet: W21,8x1/14LH nut acc. to DIN 477-1, no. 1
outlet: G 3/8 LHk male with 9mm tail-piece,
inlet gauge: 0 – 315 /200 bar
working gauge: 0 – 16/10 bar
width x height x depth: 240 x 190 x 75 mm
Application:
- Automotive Industry
- Cutting
- Manufacturing Industry
- Medical Technology
- Petrochemical Industry
- Pharmaceutical Industry
- Research & Development
- Welding
Class (purpose):
- Technical gases
Diaphragm Material:
EPDM
Flow rate:
28 Nm³/h
HP gauge scale:
200 Bar
Inlet Connection:
W 21,8 x 1/14 LH
Inlet pressure:
200 Bar
Linde Code:
32491257
LP Gauge:
LP gauge scale:
10 Bar
Material:
Brass
Outlet Connection:
G 3/8 LHk
Outlet pressure:
10 Bar
Product type:
Cylinder regulators
Regulation Type:
Double stage
Relief valve:
Standard:
DIN EN ISO 2503
Temperature range:
-20 up to +60 °C
Type of Gas:
Hydrogen (H2)
W (Width) x H (Height) x D (Depth):
240 x 190 x 75 mmmm.