Main pressure reducer Vulkan H 20/300 for AM 35 right hydrogen 14 bar according to DIN EN ISO 7291, single-stage design, burnout tested according to ISO 7291 with pre-pressure compensation for constant back pressure with falling pre-pressure, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 300 bar. Output pressure: 14 bar fixed. Maximum output: 75 Nm³/h at 20 bar back pressure. Inlet: external thread M24x1.5RHak-16S, Outlet: union nut G1/2RHk according to DIN EN 560. Inlet pressure gauge: 0 - 400/300 bar. Outlet pressure gauge: 0 - 40/20 bar. Width x Height x Depth: 210 x 190 x 75 mm. *****NOTE***** Replacement pressure reducer for automatic changeover group AM35/AM35H (20 bar fixed) This pressure reducer does NOT fit directly onto a cylinder bundle on the connection side! Please specify the system number when ordering! This main pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a purity of 5.0 with a stainless steel diaphragm SS321 (1.4541).
Application:
- Automotive Industry
- Chemical Industry
- Cutting
- Manufacturing Industry
- Petrochemical Industry
- Pharmaceutical Industry
- Research & Development
- Welding
Class (purpose):
- Technical gases
Flow rate:
75 Nm³/h
Gas Quality:
up to 5.0
HP Gauge:
HP gauge scale:
0 to 400 Bar
Inlet Connection:
M 24 x 1.5 RHak (Vareo)
Inlet pressure:
300 Bar
LP Gauge:
LP gauge scale:
0 to 40 Bar
Material:
Brass
Outlet Connection:
G 1/2 RHak (according to EN 560)
Outlet pressure:
14 Bar
Product type:
Cylinder regulators
Regulation Type:
Single stage
Type of Gas:
Hydrogen (H2)
W (Width) x H (Height) x D (Depth):
210x190x75mm.
Outlet pressure:
14Bar